Literature DB >> 31525368

Development of a competitive binding homogeneous mobility shift assay for the quantification of adalimumab levels in patient serum.

Barry D Hock1, Stewart M Smith2, Christopher J McEntyre3, Judith L McKenzie4, Christiaan Sies3, Paula E Keating2.   

Abstract

Adalimumab is a TNF specific monoclonal widely used therapeutically. Monitoring adalimumab levels is important for guiding treatment strategies and is predominantly performed using an ELISA. The homogeneous mobility shift assay (HMSA) has many advantages over an ELISA for adalimumab monitoring but current HMSA methodologies do not discriminate between adalimumab and other TNF specific monoclonals such as infliximab. The development and validation of a competitive binding HMSA (cHMSA) specific for adalimumab is reported here. The cHMSA had a lower limit of quantitation of 1.25 μg/ml and the intra-assay and inter-assay coefficents of variation (CV) were <20%. No signal was detected in adalimumab naïve control serum including those containing rheumatoid factor or infliximab. The majority (14/20) of adalimumab patient samples containing anti-adalimumab antibodies gave a cHMSA signal >3 standard deviations lower than the controls. The performance of the cHMSA and an ELISA was compared using adalimumab patient samples (n = 82). There was a strong correlation between the assays (r = 0.91) and the intra-class correlation coefficient (0.88) was indicative of good-excellent inter-assay reliability. Bland-Altman plots showed little overall bias and comparison of the sub-groups defined using cut-points (1.25 or 7.3 μg/ml) gave percent agreement (>90%) and Cohens kappa (95% CI: 0.61-0.93) values indicative of substantial-almost perfect agreement. These results demonstrate that cHMSA provides an accurate and specific method for monitoring adalimumab levels and can additionally provide an initial screen for the presence of anti-adalimumab antibodies.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Adalimumab; Drug monitoring; Homogeneous mobility shift assay

Year:  2019        PMID: 31525368     DOI: 10.1016/j.jim.2019.112672

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  2 in total

Review 1.  Approaches for the detection and analysis of antidrug antibodies to biopharmaceuticals: A review.

Authors:  Kyungah Suh; Isaac Kyei; David S Hage
Journal:  J Sep Sci       Date:  2022-03-10       Impact factor: 3.614

Review 2.  Therapeutic drug monitoring of biopharmaceuticals in inflammatory rheumatic and musculoskeletal disease: a systematic literature review informing EULAR points to consider.

Authors:  Charlotte Krieckaert; Borja Hernández-Breijo; Johanna Elin Gehin; Guillaume le Mélédo; Alejandro Balsa; Meghna Jani; Denis Mulleman; Victoria Navarro-Compan; Gertjan Wolbink; John Isaac; Astrid van Tubergen
Journal:  RMD Open       Date:  2022-06
  2 in total