| Literature DB >> 31523239 |
Haowen Pang1,2, Kui Wu3, Xiangxiang Shi1, Tao Tang1, Xiaoyang Sun1, Bo Yang1, Jingbo Wu1, Sheng Lin1,2.
Abstract
PURPOSE: In this study, we reported the safety and efficacy of hypofractionated 192Ir source stereotactic ablative brachytherapy (SABT) with coplanar template assistance for peripheral lung cancer, and compared the dosimetric parameters between SABT and stereotactic body radiotherapy (SBRT).Entities:
Keywords: 192Ir source; brachytherapy; coplanar template; peripheral lung cancer
Year: 2019 PMID: 31523239 PMCID: PMC6737569 DOI: 10.5114/jcb.2019.87218
Source DB: PubMed Journal: J Contemp Brachytherapy ISSN: 2081-2841
Characteristics of the patients
| Characteristics | Mean number (SD) |
|---|---|
| Age (years) | 55 ±8 |
| Tumor diameter (cm) | 3.8 ±1.1 (3.0-5.0) |
| Sex (No.) | |
| Male | 13 |
| Female | 20 |
| ECOG score (No.) | |
| 0 | 12 |
| 1 | 21 |
| Number of applicators | 2 ±1 |
| The mean implantation time per applicator (minutes) | 6.5 ±4.6 |
| Clinical stage | |
| I (T1N0M0) | 4 |
| II (T2N0-1M0) | 14 |
| III (T1-3N2M0) | 15 |
Fig. 1A) Robotic arm used to guide the coplanar template; B) The applicator inserted into the coplanar template guide hole
Fig. 2A) CT images with the smallest GTVL among 33 patients studied; B) CT images with the largest GTVL among 33 patients studied
Fig. 3The green, yellow, pink, and blue lines represent the 45 Gy, 30 Gy, 27 Gy, and 5 Gy isodose curves, respectively. A) CT slice images and doses for pre-SABT plan; B) CT slice images and doses for SABT plan; C) Three-dimensional map; D) Dose profile of the purple line for retrospective analysis of SABT plan; E) Dose profile of the red line for virtual SBRT plan
Number of patients with organs at risk (OARs) toxicity grade
| OARs | Grade 1 | Grade 2 | Grade 3 | Grade 4 |
|---|---|---|---|---|
| Lung | 0 | 0 | 0 | 0 |
| Heart | 0 | 0 | 0 | 0 |
| Esophagus | 0 | 0 | 0 | 0 |
| Trachea | 0 | 0 | 0 | 0 |
| Spinal cord | 0 | 0 | 0 | 0 |
| Skin | 0 | 0 | 0 | 0 |
Fig. 4PET-CT of 2 weeks pretreatment, 6th month, and 1-year post-treatment for a patient. A) PET-CT of 2 weeks pretreatment; B) PET-CT of 6th month; C) PET-CT of 1-year post-treatment
Summary of plan quality indices used for the evaluation and comparison of 1 fraction SABT and SBRT plans
| Dosimetric parameters | SABT | SBRT | |
|---|---|---|---|
| V100 (%) | 95.13 ±1.46 | 95.05 ±1.83 | 0.821 |
| V95 (%) | 98.09 ±1.09 | 97.89 ±0.92 | 0.663 |
| V90 (%) | 99.35 ±0.59 | 99.19 ±0.47 | 0.412 |
| V150 (%) | 67.32 ±5.43 | 0.00 ±0.00 | < 0.001 |
| D95% (Gy) | 30.07 ±0.09 | 30.44 ±0.16 | 0.835 |
| Dmean (Gy) | 65.42 ±3.10 | 39.25 ±1.57 | < 0.001 |
| CI | 0.89 ±0.06 | 0.91 ±0.05 | 0.154 |
SABT – stereotactic ablative brachytherapy, SBRT – stereotactic body radiotherapy, V100/V95/V90/V150 – percentage volume of the tumor target receiving 100%/95%/90%/150% of the prescription dose, respectively, D95% – dose administered to 95% of tumor target volume, CI – conformity index
Fig. 5Summaries of dosimetric parameters for OARs. A, B) Summary of dosimetric parameters for the lung; C) Summary of dosimetric parameters for the heart; D) Summary of dosimetric parameters for the esophagus; E) Summary of dosimetric parameters for the trachea; F) Summary of dosimetric parameters for the skin; G) Summary of dosimetric parameters for the spinal cord