Literature DB >> 31522727

Additivity of optical emissions applied to neodymium and praseodymium quantification in metallic didymium and (Nd,Pr)-Fe-B alloy samples by low-resolution atomic emission spectrometry: An evaluation of the mathematical approach used to solve spectral interferences.

Rodrigo Papai1, Millena Aparecida Sousa de Freitas2, Karina Torre da Fonseca2, Gilmar Alves de Almeida3, João Ricardo Filipini da Silveira2, André Luiz Nunis da Silva2, João Batista Ferreira Neto2, Célia Aparecida Lino Dos Santos2, Fernando José Gomes Landgraf4, Maciel Santos Luz5.   

Abstract

In this work, the effectiveness of a mathematical approach to solve the spectral interferences involved in the optical emission of two chemical species (neodymium and praseodymium) when using monochromators with low-resolution in atomic spectrometry is evaluated. Although recent technological advances have promoted spectrometers equipped with high-resolution monochromators, which have a great instrumental capability in the separation of nearby lines and consequently avoid spectral interferences, many laboratories still have old spectrometers installed with insufficient resolution to overcome such interferences. In order to evaluate a mathematical approach based on Lambert-Beer's Law, the optical emissions of neodymium and praseodymium were monitored on a low-resolution (200 pm) flame atomic emission spectrometry (F-AES). These two elements were strategically chosen as an application model because they exhibit similar physicochemical properties, joint occurrence in nature and because they are increasingly used in the manufacture of super-magnets, a material increasingly required by the high technology industry. The effectiveness of the mathematical approach was evaluated in three different ways: (i) by recovery of the analytes in synthetic mixtures containing known quantities of the species; (ii) by spike and recovery trials on a representative blend of dissolved samples and (iii) by comparing the results obtained with another analytical method: Inductively coupled plasma optical emission spectrometry (ICP-OES) with a higher spectral resolution. The results indicate the effectiveness of this simple mathematical approach, allow the "survival" of instruments equipped with low-resolution monochromators and demonstrate the applicability of this approach to spectral correction. In addition, this work contributes an analytical method for the quantification of neodymium and praseodymium in metallic alloy samples involved in the production of super-magnets, aiding in the strict quality control of these materials.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Additive emissions; Atomic spectrometry; Neodymium; Praseodymium; Spectral interferences; Super-magnets

Year:  2019        PMID: 31522727     DOI: 10.1016/j.aca.2019.07.049

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  1 in total

1.  Sorption Preconcentration and Analytical Determination of Cu, Zr and Hf in Waste Samarium-Cobalt Magnet Samples.

Authors:  Alexandra Alexandrovna Arkhipenko; Kseniya Vadimovna Petrova; Vasilisa Borisovna Baranovskaya
Journal:  Molecules       Date:  2022-08-18       Impact factor: 4.927

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.