Literature DB >> 31521343

Reliability of ultrasonographic measurements of bovine sole structures in relation to sole horn thickness, measured by computed tomography, and sole horn hardness.

T Tsuka1, R Nishimura2, M Hishinuma2, Y Murahata2, M Yamashita2, K Azuma2, T Osaki2, N Ito2, Y Okamoto2, T Imagawa2.   

Abstract

The goal of the present study was to determine the effect of sole horn thickness (SHT) and sole horn hardness (SHD) on ultrasonographic visualization of sole structures in the inner and outer claws of 150 Holstein-Friesian cows, and to evaluate different ultrasound frequencies for this purpose. Ultrasonographic views of the sole structure were considered complete when 3 echogenic lines, representing the ventral surface of the sole horn, the borders of the sole horn and soft-tissue layer, and the ventral surface of the distal phalanx, were seen. The proportion of complete ultrasonographic views of the sole structures, designated as the ultrasonographic visualization proportion (UVP), and the measurement errors of SHT were evaluated by comparing images from computed tomography (CT) and ultrasonography. The latter images were generated using 3 different probes, frequencies of 6.5 and 5.0 MHz, and 2 different ultrasound machines (#1 and #2) to assess the apex, middle, and heel regions of the claws. The UVP were 60.8 to 77.9% for the 6.5-MHz probe in ultrasound machine #1 (probe A), which were lower than those (>90%) for both the 5.0-MHz probe in ultrasound machine #1 (probe B) and the 5.0-MHz probe in ultrasound machine #2 (probe C). The UVP was significantly lower in claws with an SHD ≥50 units than in claws with an SHD <40 or 40 to <50 units (UVP: 77.1% compared with 93.7 and 91.4%, respectively) when measured with probe B. In claws with an SHT <10 mm, the UVP was significantly lower when SHD was ≥50 units compared with <40 or 40 to >50 units; the values were 69.0% versus 91.3 and 85.9%, respectively, for probe A, and 89.7% versus 100 and 100%, respectively, for probe B. When SHT were measured by either probes A or B in ultrasound machine #1, the proportions of claws in which ultrasonographic values were within a ±1 mm range compared with the values obtained by CT were 84.9 to 91.3% for CT-determined SHT <5 mm, 66.7 to 71.9% for CT-determined SHT 5 to <7 mm, 28.9 to 51.2% for CT-determined SHT 7 to <10 mm, and 6.2 to 19.7% for CT-determined SHT ≥10 mm. The data indicated that increased SHT was associated with a decrease in ultrasonographic measurement accuracy. In claws with an SHT <5 mm, the high proportion of ultrasonographic values that were accurate within a ±1 mm range suggests that this imaging modality would be useful in cows with thin soles.
Copyright © 2019 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  bovine claw; computed tomography; sole horn thickness; ultrasonography

Mesh:

Year:  2019        PMID: 31521343     DOI: 10.3168/jds.2018-15175

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  1 in total

1.  Ultrasonographic changes associated with the healing process in a fracture of the distal phalanx in a cow.

Authors:  Katsufumi Ooshita; Takeshi Tsuka; Yasutake Itou
Journal:  J Vet Med Sci       Date:  2020-07-08       Impact factor: 1.267

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.