Influence of two different cement space settings and three different cement types on the fit of polymer-infiltrated ceramic network material crowns manufactured using a complete digital workflow.

Rinet Dauti1, Bledar Lilaj1, Patrick Heimel2, Andreas Moritz1, Andreas Schedle3, Barbara Cvikl1,4.   

Abstract

OBJECTIVES: The study evaluates the influence of two spacer settings and three resin luting materials on the marginal and internal fit of polymer-infiltrated ceramic network (PICN) material crowns manufactured using a complete digital workflow.
METHODS: Optical impressions of fifty identical dies were performed using the 3M scanner (software version 5.0.2). Twenty crowns were designed using Ceramill Mind (version 3.4.10.1163), from which ten with spacer setting of 50 μm (G1) and ten with 80 μm (G2). Thirty crowns (spacer setting of 50 μm) were divided into three groups corresponding to the resin materials used as follows: RelyX Unicem (RX), Variolink Esthetic (VLE), and Nexus 3 (NX3). All crowns were milled from Vita Enamic blocks. After micro-CT scanning, absolute marginal discrepancy (AMD), internal gap (IG), total cement space volume (TCV), and marginal porosities (VP) were measured.
RESULTS: Significant difference was detected on the VP between the RX and NX3 group (p = 0.033). The mean values of all parameters were the following: AMD (μm): G1 182.6, G2 253.7, RX 210.8, VLE 195.5, NX3 186.6; IG (μm): G1 215.6, G2 173.1, RX 171.1, VLE 198.6, NX3 203; TCV (mm3): G1 22.9, G2 20.49, RX 17.57, VLE 17.49, NX3 20.59; VP (mm3): G1 0.26, G2 0.34, RX 0.32, VLE 0.46, NX3 0.54.
CONCLUSIONS: Fit of PICN material crowns was not significantly influenced by increasing the spacer settings and cementation with different resin materials. Additionally, RelyX Unicem showed significantly less porosities as compared with Nexus3. CLINICAL RELEVANCE: Both 50 μm and 80 μm virtual spacer settings can be suggested for the manufacture of PICN crowns when Ceramill Mind (version 3.4.10.1163) is used. Furthermore, a self-adhesive system can be recommended for the cementation.

Entities:  

Keywords:  Accuracy of fit; Cement porosities; Cement space parameters; Digital workflow; Micro-CT; Polymer-infiltrated ceramic network material

Year:  2019        PMID: 31515700     DOI: 10.1007/s00784-019-03053-1

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  1 in total

1.  Effect of Finish Line Design on the Fit Accuracy of CAD/CAM Monolithic Polymer-Infiltrated Ceramic-Network Fixed Dental Prostheses: An In Vitro Study.

Authors:  Mirza Rustum Baig; Aqdar A Akbar; Munira Embaireeg
Journal:  Polymers (Basel)       Date:  2021-12-09       Impact factor: 4.329

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.