Literature DB >> 31512322

Catheter ablation of ventricular arrhythmias originating from the para-Hisian region with reversed C-curve technique.

Jian Sun1,2, Peng-Pai Zhang1, Qun-Shan Wang1, Quan-Fu Xu1, Zhi-Quan Wang1, Ying Yu1, Qian Zhou3, Ya-Qin Han1, Wei Li1, Yi-Gang Li1.   

Abstract

AIMS: Ventricular arrhythmias (VAs) originating from the para-Hisian region represent a challenging location. The long-term success rate of catheter ablation above the septal leaflet of the tricuspid valve is not ideal. This study aimed to investigate the safety and efficacy of catheter ablation for para-Hisian VAs via a direct approach under the septal valve with reversed C-curve technique. METHODS AND
RESULTS: Twenty-five consecutive patients with para-Hisian VAs were included. Systematic mapping was performed in the right ventricle septum, including both the regions above and under the septal valve. Radiofrequency (RF) ablation was preferentially performed under the valve with reversed C-curve technique in all patients. If the ablation failed under the valve, it was then performed above the valve and even in aortic sinus cusps. The earliest ventricular activation preceding surface QRS (V-QRS) under the valve was significantly larger than that above the valve (34.8 ± 5.3 vs 27.8 ± 5.7 ms, P < .01). RF ablation under the valve with reversed C-curve technique achieved acute success in 22 of 25 (88%) patients. Junctional rhythm developed during ablation in 3 of 25 (12%) patients and no atrioventricular block occurred. In the remaining three patients, RF application above the valve failed to eliminate the VAs and one of them achieved successful ablation in the right coronary cusp. During a mean follow-up of 17.8 ± 9.4 months, no patients presented with VAs recurrence and no postprocedure complications occurred.
CONCLUSIONS: Catheter ablation under the valve with reversed C-curve technique shows to be effective and safe for para-Hisian VAs.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  catheter ablation; para-Hisian; reversed C-curve technique; tricuspid annulus; ventricular arrhythmias

Mesh:

Year:  2019        PMID: 31512322     DOI: 10.1111/jce.14170

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  2 in total

1.  A Systemic Mapping Approach for Right and Left Parahisian Ventricular Arrhythmias Ablation.

Authors:  Ling-Cong Kong; Tian Shuang; Zheng Li; Zhi-Guo Zou; Wen-Long Jiang; Jun Pu; Xin-Hua Wang
Journal:  Front Cardiovasc Med       Date:  2022-03-02

2.  Premature ventricular contractions with acute successful radiofrequency catheter ablation near the atrioventricular node using reversed C curve technique.

Authors:  Zhonghui Hu; Yunsheng Jiang; Su Wang
Journal:  BMC Cardiovasc Disord       Date:  2022-08-31       Impact factor: 2.174

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.