Literature DB >> 31510626

Coherent anti-Stokes Raman Fourier ptychography.

Sandro Heuke, Kevin Unger, Samira Khadir, Kamal Belkebir, Patrick C Chaumet, Hervé Rigneault, Anne Sentenac.   

Abstract

We present a theoretical and numerical study of coherent anti-Stokes Raman scattering Fourier ptychography microscopy (CARS-FPM), a scheme that has not been considered so far in the previously reported CARS wide-field imaging schemes. In this approach, the distribution of the Raman scatterer density of the sample is reconstructed numerically from CARS images obtained under various angles of incidences of the pump or Stokes beam. Our inversion procedure is based on an accurate vectorial model linking the CARS image to the sample and yields both the real and imaginary parts of the susceptibility, the latter giving access to the Raman information, with an improved resolution.

Entities:  

Year:  2019        PMID: 31510626      PMCID: PMC6825601          DOI: 10.1364/OE.27.023497

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  25 in total

1.  A method for achieving super-resolved widefield CARS microscopy.

Authors:  Kim M Hajek; Brad Littleton; Douglas Turk; Timothy J McIntyre; Halina Rubinsztein-Dunlop
Journal:  Opt Express       Date:  2010-08-30       Impact factor: 3.894

2.  On illumination schemes for wide-field CARS microscopy.

Authors:  I Toytman; D Simanovskii; D Palanker
Journal:  Opt Express       Date:  2009-04-27       Impact factor: 3.894

3.  Quantitative coherent anti-Stokes Raman scattering (CARS) microscopy.

Authors:  James P R Day; Katrin F Domke; Gianluca Rago; Hideaki Kano; Hiro-o Hamaguchi; Erik M Vartiainen; Mischa Bonn
Journal:  J Phys Chem B       Date:  2011-04-28       Impact factor: 2.991

4.  Wide-field vibrational phase imaging in an extremely folded box-CARS scattering geometry.

Authors:  Pascal Berto; Alexander Jesacher; Clemens Roider; Serge Monneret; Hervé Rigneault; Monika Ritsch-Marte
Journal:  Opt Lett       Date:  2013-03-01       Impact factor: 3.776

Review 5.  Histological coherent Raman imaging: a prognostic review.

Authors:  Marcus T Cicerone; Charles H Camp
Journal:  Analyst       Date:  2017-12-18       Impact factor: 4.616

6.  Multimodal nonlinear microscopy of head and neck carcinoma - toward surgery assisting frozen section analysis.

Authors:  Sandro Heuke; Olga Chernavskaia; Thomas Bocklitz; Fisseha Bekele Legesse; Tobias Meyer; Denis Akimov; Olaf Dirsch; Günther Ernst; Ferdinand von Eggeling; Iver Petersen; Orlando Guntinas-Lichius; Michael Schmitt; Jürgen Popp
Journal:  Head Neck       Date:  2016-04-21       Impact factor: 3.147

7.  Holographic coherent anti-Stokes Raman scattering bio-imaging.

Authors:  Kebin Shi; Perry S Edwards; Jing Hu; Qian Xu; Yanming Wang; Demetri Psaltis; Zhiwen Liu
Journal:  Biomed Opt Express       Date:  2012-06-27       Impact factor: 3.732

8.  Wide-field, high-resolution Fourier ptychographic microscopy.

Authors:  Guoan Zheng; Roarke Horstmeyer; Changhuei Yang
Journal:  Nat Photonics       Date:  2013-09-01       Impact factor: 38.771

9.  Pseudo-HE images derived from CARS/TPEF/SHG multimodal imaging in combination with Raman-spectroscopy as a pathological screening tool.

Authors:  Thomas W Bocklitz; Firas Subhi Salah; Nadine Vogler; Sandro Heuke; Olga Chernavskaia; Carsten Schmidt; Maximilian J Waldner; Florian R Greten; Rolf Bräuer; Michael Schmitt; Andreas Stallmach; Iver Petersen; Jürgen Popp
Journal:  BMC Cancer       Date:  2016-07-26       Impact factor: 4.430

10.  Fourier ptychographic reconstruction using Poisson maximum likelihood and truncated Wirtinger gradient.

Authors:  Liheng Bian; Jinli Suo; Jaebum Chung; Xiaoze Ou; Changhuei Yang; Feng Chen; Qionghai Dai
Journal:  Sci Rep       Date:  2016-06-10       Impact factor: 4.379

View more
  1 in total

1.  Spatial frequency modulated imaging in coherent anti-Stokes Raman microscopy.

Authors:  Sandro Heuke; Siddharth Sivankutty; Camille Scotte; Patrick Stockton; Randy A Bartels; Anne Sentenac; Hervé Rigneault
Journal:  Optica       Date:  2020-05-01       Impact factor: 11.104

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.