| Literature DB >> 31506078 |
Hui Huang1, Masashi Nagao2,3,4, Hitoshi Arita1, Jun Shiozawa1, Hirofumi Nishio1, Yohei Kobayashi1, Haruka Kaneko1, Masataka Nagayama1,5, Yoshitomo Saita1, Muneaki Ishijima1, Yuji Takazawa1,6, Hiroshi Ikeda1, Kazuo Kaneko1.
Abstract
BACKGROUND ANDEntities:
Keywords: Anterior cruciate ligament (ACL); Tampa Scale for Kinesiophobia (TSK); The consensus-based standards for the selection of health status measurement INstruments (COSMIN); Validation study
Mesh:
Year: 2019 PMID: 31506078 PMCID: PMC6737637 DOI: 10.1186/s12955-019-1217-7
Source DB: PubMed Journal: Health Qual Life Outcomes ISSN: 1477-7525 Impact factor: 3.186
Demographics of participants
| Characteristics | |
|---|---|
| Age, mean (SD), year | 32.4 (12.4) |
| Gender, n (%) | |
| Male | 141 (63.5) |
| Female | 81 (36.5) |
| BMI, mean (SD) | 24.6 (4.4) |
| Post-operative, n (%) | 184 (82.9) |
| Non-operative, n (%) | 38 (17.1) |
| Side, n (%) | |
| Left | 103 (46.4) |
| Right | 100 (45.0) |
| Bilateral | 19 (8.6) |
| Injury mechanism, n (%) | |
| Contact | 44 (17.5) |
| Noncontact | 153 (60.7) |
| Unclear | 55 (21.8) |
| Concomitant Injury, n (%) | |
| Meniscus | 120 (64.2) |
| Articular cartilage | 55 (29.4) |
| Other ligaments | 12 (6.4) |
SD standard deviation, BMI body mass index
Measurement properties of reliability
| Measurement properties | TSK-J |
|---|---|
| Cronbach’s alpha, | 0.79 (0.76 to 0.83) |
| ICC 2,1, | 0.90 (0.81 to 0.95) |
| Baseline score, Mean (SD) | 39.7 (6.75) |
| Retest score, Mean (SD) | 38.4 (6.11) |
| | 0.3426 |
| 95% CI | −1.44 to 4.09 |
| SEM, | 2.75 |
TSK-J Japanese Tampa Scale for Kinesiophobia, CI confidence interval, ICC intra-class correlation coefficient, SD standard deviation, SEM Standard error of measurement
Content validity of the TSK-J
| Characteristics | |
|---|---|
| Measurement aim | Quantifying pain, fear avoidance, fear of re-injury during movement because of a previous injury [ |
| Target population | The target population is unclear but has been widely used for low back pain and any other chronic pain [ |
| Concept | TSK has commonly been used for patients with ACL injury to evaluate psychological factors. |
TSK-J Japanese Tampa Scale for Kinesiophobia, ACL anterior cruciate ligament
Correlation between the TSK-J and other outcomes (n = 222)
| IKDC-SKF | VAS-Sports | JACL-25 | ||
|---|---|---|---|---|
| TSK-J, | −0.49 | − 0.48 | 0.48 | < 0.001 |
| IKDC-SKF, | – | 0.80 | −0.87 | < 0.001 |
| JACL-25, | −0.87 | −0.82 | – | < 0.001 |
TSK-J Japanese Tampa Scale for Kinesiophobia, IKDC-SKF International Knee Documentation Committee Subjective Knee Form, VAS-Sports Visual Analog Scale for Sports, JACL-25 Japanese Anterior Cruciate Ligament 25
Responsiveness
| TSK-J | IKDC-SKF | JACL-25 | ||
|---|---|---|---|---|
| Pre-surgery, mean (SD), | 39.3 (8.6) | 65.7 (16.7) | 64.1 (25.6) | |
| Post-surgery, mean (SD), | 38.1 (4.9) | 70.6 (13.8) | 51.0 (24.2) | |
ESa, Cohen’s d (95% CI), | 0.2 (−0.50 to 0.85) | 0.3 (−0.36 to 1.00) | 0.5 (− 0.16 to 1.21) | |
| Following Time, | −0.12 | 0.62 | −0.62 | |
| AUC, | 0.54 | 0.61 | 0.7 | |
| NS | 0.004 | 0.015 |
SD standard deviation, TSK-J Japanese Tampa Scale for Kinesiophobia, IKDC-SKF International Knee Documentation Committee Subjective Knee Form, JACL-25 Japanese Anterior Cruciate Ligament 25, AUC Area under the curve, NS no significant difference, ES effect size
aCohen’s d was calculated by the mean time interval of 10 weeks
Fig. 1Correlation between TSK-J and following time. Almost no change found in the TSK-J following time (r = − 0.12)
Fig. 2ROC between “no change” and “improved” (n = 72). ROC, receiver operating characteristics. The area under the curve (AUC) between “no change” and “improved” demonstrate fail accuracy of AUC = 0.54
Interpretability
| Characteristic | n | TSK-J |
|---|---|---|
| PGIC, mean change (SD) | ||
| Very much worse | – | – |
| Much worse | – | – |
| Minimally worse | 4 | − 2.5 (1.7) |
| No change | 17 | 0.5 (5.6) |
| Minimally improved | 16 | −0.8 (4.3) |
| Much improved | 29 | 0.4 (6.7) |
| Very much improved | 10 | −3.8 (5.8) |
| Baseline mean (SD) | 76 | 39.3 (7.3) |
| Repeat mean (SD) | 76 | 38.8 (7.0) |
| MIC | 16 | −0.8 |
| MID | 33 | −1.3 |
| SDCind | 43 | 7.6 |
| SDCgro | 43 | 1.2 |
| Ceiling effect (%) | 222 | 0 |
| Floor effect (%) | 222 | 0 |
PGIC patient global impression of change, SDC smallest detectable change for individual changes, SDC smallest detectable change for group, SD standard deviation, MIC minimal important change, MID minimal important difference, TSK-J Japanese Tampa Scale for Kinesiophobia
Correlation between each item (n = 222)
| Item No. | Correlation between TSK-J total score, |
|---|---|
| Q01 | 0.68 |
| Q02 | 0.64 |
| Q03 | 0.72 |
| Q04 | 0.27 |
| Q05 | 0.42 |
| Q06 | 0.59 |
| Q07 | 0.61 |
| Q08 | 0.20 |
| Q09 | 0.69 |
| Q10 | 0.61 |
| Q11 | 0.67 |
| Q12 | 0.57 |
| Q13 | 0.50 |
| Q14 | 0.71 |
| Q15 | 0.66 |
| Q16 | 0.05* |
| Q17 | 0.38 |
TSK-J Japanese Tampa Scale for Kinesiophobia