IMPORTANCE: Use of the trabecular micro-bypass stent with cataract surgery is well established to be safe and effective in primary open-angle glaucoma. This is the first study to exclusively evaluate use of the device in pigmentary glaucoma. BACKGROUND: This study aimed to investigate the safety and efficacy of a trabecular micro-bypass stent in combination with cataract surgery in pigmentary glaucoma. DESIGN: Retrospective, consecutive case series. PARTICIPANTS: Twenty-four eyes of 12 patients with pigmentary glaucoma implanted with one trabecular micro-bypass stent with concomitant cataract surgery. METHODS: Baseline data was collected and compared to the following postoperative time points: 1 day, 1 week, 1 month out to 36 months (M36) after the procedure. MAIN OUTCOME MEASURES: These included intraocular pressure (IOP), number of glaucoma medications and need for additional surgery. RESULTS: At M36 there was a 25% reduction in IOP to 14.68 ± 3.0 (P < .01) from 19.50 ± 6.7 mmHg at baseline. The mean number of glaucoma medications was 0.75 ± 1.0 prior to the surgery and 0.59 ± 0.6 (P > .05) at 36 M. At the 36 M time-point, 95% of eyes had IOP ≤ 18 mmHg and 68% of eyes were ≤ 15 mmHg. No eyes underwent a secondary glaucoma procedure. CONCLUSIONS AND RELEVANCE: The insertion of a single trabecular micro-bypass stent in combination with cataract surgery effectively provides a sustained reduction in IOP up to 3 years after surgery in patients with pigmentary glaucoma. The safety profile is favourable with low rate of IOP spikes and no patients requiring additional surgery.
IMPORTANCE: Use of the trabecular micro-bypass stent with cataract surgery is well established to be safe and effective in primary open-angle glaucoma. This is the first study to exclusively evaluate use of the device in pigmentary glaucoma. BACKGROUND: This study aimed to investigate the safety and efficacy of a trabecular micro-bypass stent in combination with cataract surgery in pigmentary glaucoma. DESIGN: Retrospective, consecutive case series. PARTICIPANTS: Twenty-four eyes of 12 patients with pigmentary glaucoma implanted with one trabecular micro-bypass stent with concomitant cataract surgery. METHODS: Baseline data was collected and compared to the following postoperative time points: 1 day, 1 week, 1 month out to 36 months (M36) after the procedure. MAIN OUTCOME MEASURES: These included intraocular pressure (IOP), number of glaucoma medications and need for additional surgery. RESULTS: At M36 there was a 25% reduction in IOP to 14.68 ± 3.0 (P < .01) from 19.50 ± 6.7 mmHg at baseline. The mean number of glaucoma medications was 0.75 ± 1.0 prior to the surgery and 0.59 ± 0.6 (P > .05) at 36 M. At the 36 M time-point, 95% of eyes had IOP ≤ 18 mmHg and 68% of eyes were ≤ 15 mmHg. No eyes underwent a secondary glaucoma procedure. CONCLUSIONS AND RELEVANCE: The insertion of a single trabecular micro-bypass stent in combination with cataract surgery effectively provides a sustained reduction in IOP up to 3 years after surgery in patients with pigmentary glaucoma. The safety profile is favourable with low rate of IOP spikes and no patients requiring additional surgery.
Authors: Colin Clement; Frank Howes; Alexandros S Ioannidis; Michael Shiu; David Manning; Jed Lusthaus; Ridia Lim; Simon E Skalicky; Todd Goodwin Journal: Clin Ophthalmol Date: 2020-10-28
Authors: Tanner J Ferguson; Zachary Dockter; Adam Bleeker; Kayla L Karpuk; Justin Schweitzer; Mitch J Ibach; John P Berdahl Journal: Eye Vis (Lond) Date: 2020-05-20
Authors: Colin Clement; Frank Howes; Alexandros Ioannidis; Michael Shiu; David Manning; Jed A Lusthaus; Simon E Skalicky; Todd W Goodwin Journal: Clin Ophthalmol Date: 2022-09-01