Literature DB >> 31503100

Surgical Treatment of Pelvic Discontinuity: A Systematic Review and Meta-Analysis.

Jason R Szczepanski1, Diana M Perriman1,2, Paul N Smith1,2.   

Abstract

BACKGROUND: Pelvic discontinuity is a rare condition that is treated with a range of implant constructs. However, surgical failure rates are high, and outcome data are inconsistent. It is therefore difficult to gain a clear picture of whether recently developed constructs (antiprotrusio cage [APC], cup-cage, custom triflange, and porous metal) provide better outcomes in terms of mechanical failure and complications in the short to long terms. This study investigated the failure and complication rates associated with cage constructs and porous metal technologies.
METHODS: A systematic review and meta-analysis were performed according to the Meta-analysis Of Observational Studies in Epidemiology (MOOSE) guidelines to evaluate the studies showing pelvic discontinuity in revision total hip arthroplasty. Data retrieved included the intervention performed, length of follow-up, mechanical failure, and other complication rates (dislocation, infection, neurological, loosening, migration). Study quality was assessed with the Methodological Index for Non-Randomized Studies (MINORS) instrument. Pooled mechanical failure and complication rates were calculated using MetaXL 5.3.
RESULTS: None of the included 30 articles (n = 585 hips) were of high quality. The meta-analyses revealed a mechanical failure rate of 14% for all constructs combined. Custom triflange (5%) and cup-cage (7%) had the lowest mechanical failure rates compared with the commonly used APC (25%) and porous metal (12%). The overall other complication rate was 28%, with cup-cage lower at 21% compared with APC (34%) and custom triflange (28%). Long-term evidence investigating both interventions and porous metal technology is limited.
CONCLUSIONS: Mechanical failure rates for cup-cage and custom triflange were lowest. The other complication rate for cup-cage was lower than the pooled average. The study quality was limited, indicating a need for better studies and/or a registry. LEVEL OF EVIDENCE: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Year:  2019        PMID: 31503100     DOI: 10.2106/JBJS.RVW.18.00176

Source DB:  PubMed          Journal:  JBJS Rev        ISSN: 2329-9185


  3 in total

1.  The use of a triflange salvage system for catastrophic pelvic osteolysis after failed total hip arthroplasty.

Authors:  Matthew A Siegel; Michael J Patetta; Jason Y Chen; Diego M Barragan Echenique; Mark H Gonzalez
Journal:  J Orthop       Date:  2021-04-02

2.  Good results at 2-year follow-up of a custom-made triflange acetabular component for large acetabular defects and pelvic discontinuity: a prospective case series of 50 hips.

Authors:  Marieke Scharff-Baauw; Miranda L Van Hooff; Gijs G Van Hellemondt; Paul C Jutte; Sjoerd K Bulstra; Maarten Spruit
Journal:  Acta Orthop       Date:  2021-02-15       Impact factor: 3.717

3.  Cup-Cage Solution for Massive Acetabular Defects: A Systematic Review and Meta-Analysis.

Authors:  Chao-Xin Wang; Zi-da Huang; Bai-Jian Wu; Wen-Bo Li; Xin-Yu Fang; Wen-Ming Zhang
Journal:  Orthop Surg       Date:  2020-06-03       Impact factor: 2.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.