Literature DB >> 3150042

Automated stability-indicating high-performance liquid chromatographic assay for ethinyl estradiol and (levo)norgestrel tablets.

V D Reif1, W M Eickhoff, J K Jackman, N J DeAngelis.   

Abstract

An automated high-performance liquid chromatography (HPLC) assay for ethinyl estradiol and norgestrel or levonorgestrel in oral contraceptive tablets was developed. Tablets were prepared for on-line injection using a solid sampler and segmented continuous flow techniques. The active components were separated from tablet excipients, impurities, and degradation products on reversed-phase C8 and C18 columns by elution with water-acetonitrile-methanol (45:35:15). A UV detector connected in series with a fluorometric detector measured the UV absorbance of levonorgestrel and norgestrel at 240 nm and the fluorescence of ethinyl estradiol at 310 nm (excitation at 210 nm). The method employed computer control of the injection system and solid sampler for synchronization of the chromatographic and segmented flow streams. The method is applicable for content uniformity and stability testing at a rate of eight samples per hour.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3150042     DOI: 10.1023/a:1016434028376

Source DB:  PubMed          Journal:  Pharm Res        ISSN: 0724-8741            Impact factor:   4.200


  8 in total

1.  [Identification of 1,3,5(10)-Estratiene-6-ones].

Authors:  H Hofmeister; H Laurent; R Wiechert
Journal:  Chem Ber       Date:  1973

2.  Synthesis of compounds of potential value in the radioimmunoassay of 17 alpha-ethynylestradiol and mestranol.

Authors:  P N Rao
Journal:  Steroids       Date:  1974-02       Impact factor: 2.668

3.  The identification of some human metabolites of norgestrel, a new progestational agent.

Authors:  D C DeJongh; J D Hribar; P Littleton; K Fotherby; R W Rees; S Shrader; T J Foell; H Smith
Journal:  Steroids       Date:  1968-05       Impact factor: 2.668

4.  Automated colorimetric analysis of ethinyl estradiol and mestranol in pharmaceutical tablets.

Authors:  W F Beyer
Journal:  J Pharm Sci       Date:  1968-08       Impact factor: 3.534

5.  Automated colorimetric assay of norgestrel.

Authors:  P M Short; C T Rhodes
Journal:  Steroids       Date:  1970-08       Impact factor: 2.668

6.  Fluorometric determination of norgestrel and structurally related steroids.

Authors:  L F Cullen; J G Rutgers; P A Lucchesi; G J Papariello
Journal:  J Pharm Sci       Date:  1968-11       Impact factor: 3.534

7.  Determination of ethinyloestradiol in single tablets and its separation from other steroids by high-performance liquid chromatography.

Authors:  K R Bagon; E W Hammond
Journal:  Analyst       Date:  1978-02       Impact factor: 4.616

8.  Automatic determination of ethinyl estradiol in pharmaceutical preparations.

Authors:  A J Khoury; L J Cali
Journal:  J Pharm Sci       Date:  1967-11       Impact factor: 3.534

  8 in total