Literature DB >> 31499459

Utility of the Ion S5™ and MiSeq FGx™ sequencing platforms to characterize challenging human remains.

Kyleen Elwick1, Magdalena M Bus2, Jonathan L King2, Joseph Chang3, Sheree Hughes-Stamm4, Bruce Budowle2.   

Abstract

Often in missing persons' and mass disaster cases, the samples remaining for analysis are hard tissues such as bones, teeth, nails, and hair. These remains may have been exposed to harsh environmental conditions, which pose challenges for downstream genotyping. Short tandem repeat analysis (STR) via capillary electrophoresis (CE) is still the gold standard for DNA typing; however, a newer technology known as massively parallel sequencing (MPS) could improve upon our current techniques by typing different and more markers in a single analysis, and consequently improving the power of discrimination. In this study, bone and tooth samples exposed to a variety of DNA insults (cremation, embalming, decomposition, thermal degradation, and fire) were assessed and sequenced using the Precision ID chemistry and a custom AmpliSeq™ STR and iiSNP panel on the Ion S5™ System, and the ForenSeq DNA Signature Prep Kit on the MiSeq FGx™ system, as well as the GlobalFiler™ PCR Amplification Kit on the 3500™ Genetic Analyzer. The results demonstrated that using traditional CE-based genotyping performed as expected, producing a partial or full DNA profile for all samples, and that both sequencing chemistries and platforms were able to recover sufficient STR and SNP information from a majority of the same challenging samples. Run metrics including profile completeness and mean read depth produced good results with each system, considering the degree of damage of some samples. Most sample insults (except decomposed) produced similar numbers of alleles for both MPS systems. Comparable markers produced full concordance between the two platforms.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Challenged remains; Human remains; Ion S5™; Massively parallel sequencing; MiSeq FGx™; Missing persons

Mesh:

Substances:

Year:  2019        PMID: 31499459     DOI: 10.1016/j.legalmed.2019.08.001

Source DB:  PubMed          Journal:  Leg Med (Tokyo)        ISSN: 1344-6223            Impact factor:   1.376


  2 in total

1.  Sequencing of human identification markers in an Uyghur population using the MiSeq FGxTM Forensic Genomics System.

Authors:  Halimureti Simayijiang; Niels Morling; Claus Børsting
Journal:  Forensic Sci Res       Date:  2020-09-10

2.  Concordance and characterization of massively parallel sequencing at 58 STRs in a Tibetan population.

Authors:  Hui Li; Cheng Zhang; Guoqing Song; Ke Ma; Yu Cao; Xueying Zhao; Qinrui Yang; Jianhui Xie
Journal:  Mol Genet Genomic Med       Date:  2021-02-25       Impact factor: 2.183

  2 in total