Literature DB >> 31498417

Refractive and Visual Outcomes of SUPRACOR TENEO 317 LASIK for Presbyopia in Hyperopic Eyes: 24-Month Follow-up.

José-María Sánchez-González, Federico Alonso-Aliste, Jonatan Amián-Cordero, María Carmen Sánchez-González, Concepción De-Hita-Cantalejo.   

Abstract

PURPOSE: To analyze the efficacy, safety, predictability, and stability in hyperopic presbyopic laser in situ keratomileusis (LASIK) surgeries with the TENEO 317 algorithm (Bausch & Lomb Technolas, Munich, Germany).
METHODS: Eighty eyes from 40 patients who underwent hyperopic and presbyopic LASIK in this retrospective, observational, and longitudinal study were included. All patients had a 24-month follow-up. Excimer laser treatment was performed with TECNOLAS Perfect Vision GmbH TENEO 317 software version 1.25 (Bausch & Lomb) with the PROSCAN platform for the distance dominant eye and the SUPRACOR mild platform for the near dominant eye.
RESULTS: Mean age was 53.90 ± 4.84 years (range: 42 to 66 years). Postoperative uncorrected distance visual acuity (UDVA) was 0.00 ± 0.04 (20/19.97) for the dominant eye and 0.14 ± 0.05 (20/27.65) for the non-dominant eye. Postoperative uncorrected near visual acuity was 0.51 ± 0.17 (J9) for the dominant eye and 0.09 ± 0.06 (J1.5) for the non-dominant eye, whereas 2.5% of non-dominant eyes lost two lines of corrected distance visual acuity. Half of non-dominant eyes lost one line, and 2.5% of dominant and non-dominant eyes changed 0.50 D or more between 3 and 24 months.
CONCLUSIONS: PROSCAN surgery in the dominant eye and SUPRACOR surgery in the non-dominant eye using the TENEO 317 algorithm demonstrated that the hyperopic presbyopic excimer laser surgery technique resulted in acceptable and stable outcomes after 24 months of follow-up. [J Refract Surg. 2019;35(9):591-598.]. Copyright 2019, SLACK Incorporated.

Entities:  

Mesh:

Year:  2019        PMID: 31498417     DOI: 10.3928/1081597X-20190815-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  2 in total

Review 1.  Refractive corneal inlay implantation outcomes: a preliminary systematic review.

Authors:  José-María Sánchez-González; Davide Borroni; Rahul Rachwani-Anil; Carlos Rocha-de-Lossada
Journal:  Int Ophthalmol       Date:  2021-10-02       Impact factor: 2.031

Review 2.  PresbyLASIK: A review of PresbyMAX, Supracor, and laser blended vision: Principles, planning, and outcomes.

Authors:  Rohit Shetty; Sheetal Brar; Mohita Sharma; Zelda Dadachanji; Vaitheeswaran Ganesan Lalgudi
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.