Literature DB >> 31498274

Cervical Spine Computed Tomography Hounsfield Units Accurately Predict Low Bone Mineral Density of the Femoral Neck.

Donald F Colantonio1, Sameer K Saxena1, Alan Vanier2, Daniel Rodkey1, Scott Tintle1, Scott C Wagner1.   

Abstract

STUDY
DESIGN: A retrospective cohort.
OBJECTIVE: The objective of this study to determine the correlation between Hounsfield unit (HU) measurements from the C4 vertebral body and dual-energy x-ray absorptiometry (DXA) T-score. SUMMARY OF BACKGROUND DATA: Recent attention has turned to the utilization of HU measurements from computed tomography (CT) as a potential screening method for low bone mineral density (BMD). We hypothesized that cervical spine CT HU measurements will correlate with BMD measurements conducted with DXA scans of the femoral neck.
MATERIAL AND METHODS: Patients with cervical CT and femoral neck DXA scans at 1 institution were included in the study. HUs were manually measured from the cancellous bone in the C4 vertebrae by 1 author blinded to DXA scans. HU measurements were compared with femoral neck DXA T-scores for the entire population.
RESULTS: A total of 149 patients with 149 cervical CT and femoral neck DXA scans were included in the study. The low BMD group (osteoporotic and osteopenic combined) showed a significant difference in HU compared with the normal groups within the study (P<0.0001). A low BMD screening value of 447 HU captured over 95% of patients with low BMD within our study and provided a sensitivity of 92% and negative predictive value of 82.1%. The male and female intrasex analysis demonstrated a significant difference between the low BMD and normal BMD groups with P=0.001 and P=0.0001, respectively.
CONCLUSIONS: HU measurements taken from the C4 vertebral body on CT scan correlate with low BMD of the femoral neck as determined by DXA scan T-scores. Screening values of 447 HU captured 95% of patients with low BMD, with a high degree of sensitivity, and negative predictive value of 80%. Utilization of cervical spine HU as a screening method provides a simple, quick, and easily assessable screening tool for assessing low BMD. LEVEL OF EVIDENCE: Level III-diagnostic.

Entities:  

Mesh:

Year:  2020        PMID: 31498274     DOI: 10.1097/BSD.0000000000000879

Source DB:  PubMed          Journal:  Clin Spine Surg        ISSN: 2380-0186            Impact factor:   1.876


  5 in total

1.  Evaluation of the serum level of osteoprotegerin and bone mineral density in postmenopausal women.

Authors:  Hossein Abdollahi Veshnavei
Journal:  Int J Physiol Pathophysiol Pharmacol       Date:  2022-02-15

2.  Low cervical vertebral CT value increased early subsidence of titanium mesh cage after anterior cervical corpectomy and fusion.

Authors:  Zhiqiang Wang; Jun Mei; Xiaoning Feng; Chen Deng; Xuefeng Tian; Junqiao Lv; Lin Sun
Journal:  J Orthop Surg Res       Date:  2022-07-16       Impact factor: 2.677

3.  [Insufficiency fractures of the spine in relation to cancellous bone density : An in vitro study].

Authors:  Guido Schröder; Dirk Flachsmeyer; Claus Maximilian Kullen; Julian Ramin Andresen; Marko Schulze; Laura Hiepe; Hans-Christof Schober; Reimer Andresen
Journal:  Orthopadie (Heidelb)       Date:  2022-05-23

4.  Low-dose CT hounsfield units: a reliable methodology for assessing vertebral bone density in radiographic axial spondyloarthritis.

Authors:  Mary Lucy Marques; Nuno Pereira da Silva; Desirée van der Heijde; Monique Reijnierse; Xenofon Baraliakos; Juergen Braun; Floris A van Gaalen; Sofia Ramiro
Journal:  RMD Open       Date:  2022-06

5.  Hounsfield Unit for Assessing Bone Mineral Density Distribution Within Cervical Vertebrae and Its Correlation With the Intervertebral Disc Degeneration.

Authors:  Xiao Liang; Qingtao Liu; Jiaxin Xu; Wenyuan Ding; Hui Wang
Journal:  Front Endocrinol (Lausanne)       Date:  2022-07-08       Impact factor: 6.055

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.