Literature DB >> 31494558

Fully Integrated, Automated, and Smartphone Enabled Point-of-Source Portable Platform With Microfluidic Device for Nitrite Detection.

Sohan Dudala, Satish Kumar Dubey, Sanket Goel.   

Abstract

Excess limit of Nitrites, which are prevalent within environmental and physiological systems, have severe detrimental effects, thus point-of-source detection becomes an important requirement to take suitable preventive measures. This paper presents the design and development of a standalone, point-of-source, portable, low-cost, automated and integrated microfluidic system for quick detection and quantification of nitrite. Based on multiphysics simulations, a disposable polydimethylsiloxane (PDMS) microfluidic device was employed to carry out the controlled Griess reaction based assay. A low-cost 3D printed syringe pump was developed to inject the sample and reagent. Photometric detection was employed using light emitting diode (LED) and photodiode. A transimpedance amplifier circuit was designed and fabricated to achieve amplified photodiode output with reduced noise. An off-the-shelf microprocessor was used to integrate the whole system and a smartphone application (app) was developed to control the complete system and store the data. Interaction between the application and the microprocessor was achieved using Bluetooth connectivity. Spectrophotometric validation was performed and a calibration equation was obtained which was used to convert the device voltage output to absorption, through specially programmed android app. All the components were integrated in a 3D printed platform whose virtues such as ease of usage and affordability makes, quantification of nitrite, a simple and real time process wherein the limit of detection and limit of quantification values are found to be 0.07103 ppm and 0.21524 ppm respectively with good repeatability.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31494558     DOI: 10.1109/TBCAS.2019.2939658

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  4 in total

1.  Monolithic Integrated OLED-OPD Unit for Point-of-Need Nitrite Sensing.

Authors:  Igor Titov; Markus Köpke; Martina Gerken
Journal:  Sensors (Basel)       Date:  2022-01-25       Impact factor: 3.576

2.  Easy Nitrite Analysis of Processed Meat with Colorimetric Polymer Sensors and a Smartphone App.

Authors:  Marta Guembe-García; Lara González-Ceballos; Ana Arnaiz; Miguel A Fernández-Muiño; M Teresa Sancho; Sandra M Osés; Saturnino Ibeas; Jordi Rovira; Beatriz Melero; Cesar Represa; José M García; Saúl Vallejos
Journal:  ACS Appl Mater Interfaces       Date:  2022-08-03       Impact factor: 10.383

Review 3.  Recent Advances in Flexible RF MEMS.

Authors:  Yingli Shi; Zhigang Shen
Journal:  Micromachines (Basel)       Date:  2022-07-08       Impact factor: 3.523

4.  Nitrite enhanced detection from saliva by simple geometrical modifications of paper-based micromixers.

Authors:  Elham Mollaie; Sasan Asiaei; Hiwa Aryan
Journal:  Microfluid Nanofluidics       Date:  2022-10-12       Impact factor: 3.090

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.