Inorganic scintillation detectors for 192Ir brachytherapy.

Gustavo Kertzscher1, Sam Beddar.   

Abstract

Many brachytherapy (BT) errors could be detected with real-time in vivo dosimetry technology. Inorganic scintillation detectors (ISDs) have demonstrated promising capabilities for BT, because some ISD materials can generate scintillation signals large enough that (a) the background signal emitted in the fiber-optic cable (stem signal) is insignificant, and (b) small detector volumes can be used to avoid volume averaging effects in steep dose gradients near BT sources. We investigated the characteristics of five ISD materials to identify one that is appropriate for BT. ISDs consisting of a 0.26 to 1.0 mm3 volume of ruby (Al2O3:Cr), a mixture of Y2O3:Eu and YVO4:Eu, ZnSe:O, or CsI:Tl coupled to a fiber-optic cable were irradiated in a water-equivalent phantom using a high-dose-rate 192Ir BT source. Detectors based on plastic scintillators BCF-12 and BCF-60 (0.8 mm3 volume) were used as a reference. Measurements demonstrated that the ruby, Y2O3:Eu+YVO4:Eu, ZnSe:O, and CsI:Tl ISDs emitted scintillation signals that were up to 19, 19, 250, and 880 times greater, respectively, than that of the BCF-12 detector. While the total signals of the plastic scintillation detectors were dominated by the stem signal for source positions 0.5 cm from the fiber-optic cable and  >3.5 cm from the scintillator volume, the stem signal for the ruby and Y2O3:Eu+YVO4:Eu ISDs were  <1% of the total signal for source positions  <3.4 and  <4.4 cm from the scintillator, respectively, and  <0.7% and  <0.5% for the ZnSe:O and CsI:Tl ISDs, respectively, for positions  ⩽8.0 cm. In contrast to the other ISDs, the Y2O3:Eu+YVO4:Eu ISD exhibited unstable scintillation and significant afterglow. All ISDs exhibited significant energy dependence, i.e. their dose response to distance-dependent 192Ir energy spectra differed significantly from the absorbed dose in water. Provided that energy dependence is accounted for, ZnSe:O ISDs are promising for use in error detection and patient safety monitoring during BT.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31491777     DOI: 10.1088/1361-6560/ab421f

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

Review 1.  Recent Advances in Optical Fiber Enabled Radiation Sensors.

Authors:  Jing Zhang; Yudiao Xiang; Chen Wang; Yunkang Chen; Swee Chuan Tjin; Lei Wei
Journal:  Sensors (Basel)       Date:  2022-02-01       Impact factor: 3.576

2.  Toward 3D dose verification of an electronic brachytherapy source with a plastic scintillation detector.

Authors:  Peter Georgi; Gustavo Kertzscher; Lars Nyvang; Jaroslav Šolc; Thorsten Schneider; Kari Tanderup; Jacob Graversen Johansen
Journal:  Med Phys       Date:  2022-03-03       Impact factor: 4.506

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.