Literature DB >> 31486814

Influence of the Accuracy of Intraoral Scanbodies on Implant Position: Differences in Manufacturing Tolerances.

Alexander Schmidt, Jan-Wilhelm Billig, Maximiliane A Schlenz, Peter Rehmann, Bernd Wöstmann.   

Abstract

PURPOSE: To assess the manufacturing tolerances of three different intraoral scanbodies (ISBs) and their possible influence on the transfer of the intraoral implant position to the digital cast.
MATERIALS AND METHODS: Three different ISBs were measured using x-ray computed tomography. The length, diameter, angle, and target volume deviation were analyzed, and the data were subjected to a univariate analysis of variance.
RESULTS: There were significant differences between all three ISBs in length, diameter, and target volume deviations (P < .05).
CONCLUSION: Manufacturing tolerances of ISBs have the potential to decisively affect the transfer accuracy of the implant position from the recorded intraoral position to the digital cast, which needs to be considered.

Mesh:

Substances:

Year:  2019        PMID: 31486814     DOI: 10.11607/ijp.6371

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  5 in total

1.  A new 3D-method to assess the inter implant dimensions in patients - A pilot study.

Authors:  Alexander Schmidt; Jan-Wilhelm Billig; Maximiliane A Schlenz; Bernd Wöstmann
Journal:  J Clin Exp Dent       Date:  2020-02-01

Review 2.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

3.  Effect of Implant Angulation on the Rotational Displacement of a 3-Unit Bridge after Digital Impression.

Authors:  Mahnaz Arshad; Amirmohsen Asgari; Mohamad Javad Kharazifard; Narges Ameri
Journal:  Int J Dent       Date:  2022-01-25

4.  Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation.

Authors:  Francesco Guido Mangano; Matteo Bonacina; Federico Mandelli; Fabio Marchiori
Journal:  BMC Res Notes       Date:  2020-11-03

5.  Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study.

Authors:  Francesco Guido Mangano; Oleg Admakin; Matteo Bonacina; Henriette Lerner; Vygandas Rutkunas; Carlo Mangano
Journal:  BMC Oral Health       Date:  2020-09-22       Impact factor: 2.757

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.