Literature DB >> 31484133

Optical and Electromagnetic Tracking Systems for Biomedical Applications: A Critical Review on Potentialities and Limitations.

Angela Sorriento, Maria Bianca Porfido, Stefano Mazzoleni, Giuseppe Calvosa, Miria Tenucci, Gastone Ciuti, Paolo Dario.   

Abstract

Optical and electromagnetic tracking systems represent the two main technologies integrated into commercially-available surgical navigators for computer-assisted image-guided surgery so far. Optical Tracking Systems (OTSs) work within the optical spectrum to track the position and orientation, i.e., pose of target surgical instruments. OTSs are characterized by high accuracy and robustness to environmental conditions. The main limitation of OTSs is the need of a direct line-of-sight between the optical markers and the camera sensor, rigidly fixed into the operating theatre. Electromagnetic Tracking Systems (EMTSs) use electromagnetic field generator to detect the pose of electromagnetic sensors. EMTSs do not require such a direct line-of-sight, however the presence of metal or ferromagnetic sources in the operating workspace can significantly affect the measurement accuracy. The aim of the proposed review is to provide a complete and detailed overview of optical and electromagnetic tracking systems, including working principles, source of error and validation protocols. Moreover, commercial and research-oriented solutions, as well as clinical applications, are described for both technologies. Finally, a critical comparative analysis of the state of the art which highlights the potentialities and the limitations of each tracking system for a medical use is provided.

Entities:  

Mesh:

Year:  2019        PMID: 31484133     DOI: 10.1109/RBME.2019.2939091

Source DB:  PubMed          Journal:  IEEE Rev Biomed Eng        ISSN: 1937-3333


  9 in total

1.  Assessment of the Mechanical Support Characteristics of a Light and Wearable Robotic Exoskeleton Prototype Applied to Upper Limb Rehabilitation.

Authors:  Manuel Andrés Vélez-Guerrero; Mauro Callejas-Cuervo; Juan C Álvarez; Stefano Mazzoleni
Journal:  Sensors (Basel)       Date:  2022-05-25       Impact factor: 3.847

Review 2.  Registration Techniques for Clinical Applications of Three-Dimensional Augmented Reality Devices.

Authors:  Christopher M Andrews; Alexander B Henry; Ignacio M Soriano; Michael K Southworth; Jonathan R Silva
Journal:  IEEE J Transl Eng Health Med       Date:  2020-12-17       Impact factor: 3.316

3.  Design and analysis of a fiber-optic sensing system for shape reconstruction of a minimally invasive surgical needle.

Authors:  Aizhan Issatayeva; Aida Amantayeva; Wilfried Blanc; Daniele Tosi; Carlo Molardi
Journal:  Sci Rep       Date:  2021-04-21       Impact factor: 4.379

4.  Planar Body-Mounted Sensors for Electromagnetic Tracking.

Authors:  Marco Cavaliere; Herman Alexander Jaeger; Kilian O'Donoghue; Pádraig Cantillon-Murphy
Journal:  Sensors (Basel)       Date:  2021-04-16       Impact factor: 3.576

5.  Electronically integrated microcatheters based on self-assembling polymer films.

Authors:  Boris Rivkin; Christian Becker; Balram Singh; Azaam Aziz; Farzin Akbar; Aleksandr Egunov; Dmitriy D Karnaushenko; Ronald Naumann; Rudolf Schäfer; Mariana Medina-Sánchez; Daniil Karnaushenko; Oliver G Schmidt
Journal:  Sci Adv       Date:  2021-12-17       Impact factor: 14.136

6.  Comparing optical and electromagnetic tracking systems to facilitate compatibility in sports kinematics data.

Authors:  Caryn A Urbanczyk; Alessandro Bonfiglio; Alison H McGregor; Anthony M J Bull
Journal:  Int Biomech       Date:  2021-12

7.  Application of an Optical Tracking System for Motor Skill Assessment in Laparoscopic Surgery.

Authors:  Lixiao Yang; Kunyong Lyu; Chengli Song
Journal:  Comput Math Methods Med       Date:  2022-07-22       Impact factor: 2.809

8.  Puncture accuracy of an optical tracked robotic aiming device-a phantom study.

Authors:  Yannick Scharll; Sofia Letrari; Gregor Laimer; Peter Schullian; Reto Bale
Journal:  Eur Radiol       Date:  2022-06-09       Impact factor: 7.034

9.  A Radiolucent Electromagnetic Tracking System for Use with Intraoperative X-ray Imaging.

Authors:  Kilian O'Donoghue; Herman Alexander Jaeger; Padraig Cantillon-Murphy
Journal:  Sensors (Basel)       Date:  2021-05-12       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.