Literature DB >> 31483574

Three-dimensional rotational angiography in congenital heart disease: Present status and evolving future.

Sok-Leng Kang1, Aimee Armstrong2, Gregor Krings3, Lee Benson1.   

Abstract

Three-dimensional rotational angiography (3D-RA) enables volumetric imaging through rotation of the C-arm of an angiographic system and real-time 3D reconstruction during cardiac catheterization procedures. In the field of congenital heart disease (CHD), 3D-RA has gained considerable traction, owing to its capability for enhanced visualization of spatial relationships in complex cardiac morphologies and real time image guidance in an intricate interventional environment. This review provides an overview of the current applications, strengths, and limitations of 3D-RA acquisition in the management of CHD and potential future directions. In addition, issues of dosimetry, radiation exposure, and optimization strategies will be reviewed. Further implementation of 3D-RA will be driven by patient benefits relative to existing 3D imaging capabilities and fusion techniques balanced against radiation exposure.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  angiography; cardiac catheterization; congenital heart defects; rotational; three-dimensional imaging

Mesh:

Year:  2019        PMID: 31483574     DOI: 10.1111/chd.12838

Source DB:  PubMed          Journal:  Congenit Heart Dis        ISSN: 1747-079X            Impact factor:   2.007


  3 in total

1.  Troubled Judging of Bronchus Compression Due to Contrast-Filled Balloon in Three-Dimensional Rotational Angiography.

Authors:  Anouk S Moerdijk; Johannes M P J Breur; Mirella M C Molenschot; Gregor J Krings
Journal:  Pediatr Cardiol       Date:  2022-01-16       Impact factor: 1.655

2.  Renaissance of Cardiac Imaging to Assist Percutaneous Interventions in Congenital Heart Diseases:The Role of Three-Dimensional Echocardiography and Multimodality Imaging.

Authors:  Martina Avesani; Sok-Leng Kang; Zakaria Jalal; Jean-Benoit Thambo; Xavier Iriart
Journal:  Front Pediatr       Date:  2022-05-19       Impact factor: 3.569

3.  Comparison of pulmonary artery dimensions in swine obtained from catheter angiography, multi-slice computed tomography, 3D-rotational angiography and phase-contrast magnetic resonance angiography.

Authors:  Ryan Pewowaruk; Klarka Mendrisova; Carolina Larrain; Christopher J Francois; Alejandro Roldán-Alzate; Luke Lamers
Journal:  Int J Cardiovasc Imaging       Date:  2020-10-09       Impact factor: 2.357

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.