A common type of commercially available LED light source allows for colour discrimination performance at a level comparable to halogen lighting.

Sara Königs1, Susanne Mayr2, Axel Buchner1.   

Abstract

As light sources based on light emitting diodes (LED) are increasingly used to replace classic tungsten-based light sources in household lighting applications, possible impairments of colour perception under those light sources due to a different spectral power distribution become a major concern. The Colour Rendering Index (CRI) which is the only measure available to the end user is controversial and does not represent a comprehensive measure of colour perception. Aspects of colour perception disregarded by the CRI such as colour discrimination have to be taken into account as well. Therefore, we evaluated colour discrimination performance under a commercially available phosphor-converted LED light source from a popular brand (OSRAM) in comparison to a classic tungsten-based halogen light source. Colour discrimination performance was not affected by the type of light source, indicating that the phosphor-converted LED light source enables colour discrimination performance comparable to that of halogen lighting despite being associated with a lower CRI. Practitioner summary: Considering the increasing use of energy efficient light sources, we compared colour discrimination under a common type of phosphor-converted LED and under traditional halogen lighting. Colour discrimination performance was comparable in both lighting conditions, indicating that the phosphor-converted LED can replace halogen lighting without sacrificing colour discrimination for energy efficiency. Abbreviations: LED: light emitting diode; CRI: colour rendering index; CCT: correlated colour temperature; CIE: commission internationale de l'éclairage; FMHT: Farnsworth-Munsell 100-Hue Test; lm: lumen; lx: lux, lumen/m^2; W: watt; nm: nanometer; K: kelvin.

Entities:  

Keywords:  Phosphor-converted LED; colour discrimination; halogen lamp; illuminance level

Mesh:

Year:  2019        PMID: 31482767     DOI: 10.1080/00140139.2019.1663940

Source DB:  PubMed          Journal:  Ergonomics        ISSN: 0014-0139            Impact factor:   2.778


  2 in total

1.  Effect of dental headlights spectrum on the polymerization and working time of light-cured resin composites.

Authors:  Mateus-Garcia Rocha; Marc-Edward Ottenga; Panagiotis Zoidis; Stefany Pontes; Andre-Figueiredo Reis; Dayane Oliveira
Journal:  J Clin Exp Dent       Date:  2022-06-01

2.  Investigation of Electrical Properties and Reliability of GaN-Based Micro-LEDs.

Authors:  Ke Zhang; Yibo Liu; Hoi-Sing Kwok; Zhaojun Liu
Journal:  Nanomaterials (Basel)       Date:  2020-04-06       Impact factor: 5.076

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.