Literature DB >> 31482183

Internal rotation of the tibial component in total knee arthroplasty can lead to extension deficit.

Mohammad Kamal Abdelnasser1,2, Mohammad Muath Adi3, Ahmed Aly Elnaggar4, Samih Tarabichi5.   

Abstract

PURPOSE: Stiffness is a common problem following total knee arthroplasty (TKA). Mal-rotated components have been claimed to be the major cause of pain and limited motion after TKA. The present study investigates whether intra-operative intentional malrotation of the tibial component would change in vivo kinematics. The hypothesis is excessive internal rotation of the tibial component would result in postoperative extension deficit.
METHODS: Thirty-one patients were enrolled in this study. After completing bony cuts and proper soft tissue balancing, the femoral and tibial trials were impacted and fixed using small pins. Lateral radiographs were used to measure and compare intraoperative full knee extension during normal and after intentional internal rotation of the tibial component. The extension deficit angles were also compared between the posterior stabilised (PS) and cruciate retaining (CR) implants.
RESULTS: For normal tibial component rotation, the median (interquartile range) extension deficit was 0° (4). The mean tibial trial intentional internal rotation was 21.2° (± 4.5). The median (interquartile range) extension deficit significantly increased to 6° (4) after tibial component internal rotation (p = 0.001). The use of PS spacers resulted in a significantly greater extension deficit after intentional internal rotation 9° (5) compared to that of the CR implant 1° (4) (p = 0.001).
CONCLUSION: Internal rotation of the tibial component in total knee arthroplasty can lead to postoperative extension deficit. This could be attributed to interference with "screw home" mechanism that requires full external rotation of the tibia on the femur. Consequently, this deficit may cause pain and knee stiffness following TKA. LEVEL OF EVIDENCE: III.

Entities:  

Keywords:  Extension deficit; Internal rotation; Tibial component; Total knee arthroplasty

Year:  2019        PMID: 31482183     DOI: 10.1007/s00167-019-05695-w

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  7 in total

1.  Finite element analysis of the tibial component alignment in a transverse plane in total knee arthroplasty.

Authors:  Roman Popescu; Stefan Cristea; Valentin Oleksik; Adrian Marius Pascu; Emil George Haritinian
Journal:  J Appl Biomed       Date:  2021-09-20       Impact factor: 1.797

2.  The personalized Berger method is usable to solve the problem of tibial rotation.

Authors:  Gömöri András; Gábor Németh; Csaba Zsolt Oláh; Gábor Lénárt; Zsanett Drén; Miklós Papp
Journal:  J Exp Orthop       Date:  2021-12-11

3.  Does the anatomic design of total knee prosthesis allow for a better component fit than its nonanatomic predecessor? A matched cohort Study.

Authors:  Bartosz M Maciąg; Artur Stolarczyk; Grzegorz J Maciąg; Monika Dorocińska; Piotr Stępiński; Jakub Szymczak; Maciej Świercz; Krystian Żarnovsky; Marcin Łapiński; Magda Stolarczyk
Journal:  Arthroplast Today       Date:  2021-11-01

4.  Gender differences affect the location of the patellar tendon attachment site for tibial rotational alignment in total knee arthroplasty.

Authors:  Le-Shu Zhang; Jin-Cheng Zhang; Hang Zhou; Qiang Zhang; Xiang-Yang Chen; Shuo Feng
Journal:  J Orthop Surg Res       Date:  2022-07-26       Impact factor: 2.677

5.  Moderate External Rotation of Tibial Component Generates More Natural Kinematics Than Internal Rotation After Total Knee Arthroplasty.

Authors:  Chaohua Fang; Yichao Luan; Zhiwei Wang; Long Shao; Tiebing Qu; Cheng-Kung Cheng
Journal:  Front Bioeng Biotechnol       Date:  2022-07-13

6.  Different tibial rotational axes can be applied in combination according to the tibial tuberosity-posterior cruciate ligament distance in total knee arthroplasty.

Authors:  Le-Shu Zhang; Hang Zhou; Jin-Cheng Zhang; Qiang Zhang; Xiang-Yang Chen; Shuo Feng
Journal:  BMC Musculoskelet Disord       Date:  2022-10-10       Impact factor: 2.562

7.  Influence of surgical factors on patient satisfaction after bi-cruciate stabilized total knee arthroplasty: retrospective examination using multiple regression analysis.

Authors:  Hiroshi Inui; Shuji Taketomi; Ryota Yamagami; Kenichi Kono; Kohei Kawaguchi; Kosuke Uehara; Sakae Tanaka
Journal:  BMC Musculoskelet Disord       Date:  2021-02-23       Impact factor: 2.362

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.