Literature DB >> 31478846

Characterization of Hand Tendons Through High-Frequency Ultrasound Elastography.

Pei-Yu Chen, Tai-Hua Yang, Li-Chieh Kuo, Cho-Chiang Shih, Chih-Chung Huang.   

Abstract

Tendon stiffness plays an important role in the tendon healing process, and many studies have indicated that measuring the shear wave velocity (SWV) on tendons relates to their stiffness. Because the thickness of hand tendons is a few millimeters, high-resolution imaging is required for visualizing hand tissues. However, the resolution of current ultrasound elastography systems is insufficient. In this study, a high-frequency (HF) ultrasound elastography system is proposed for measuring the SWVs of hand tendons. The HF ultrasound elastography system uses an external vibrator to create shear waves on hand tendons. Then, it uses a 40-MHz HF ultrasound array transducer with ultrafast ultrasound imaging technology to measure the SWV for characterizing hand tendons. A handheld device that combines a transducer and a vibrator allows the user to scan hand tissues. The biases of HF ultrasound elastography were measured in gelatin phantom experiments and were less than 6% compared to standard mechanical testing approach. Human experiments showed the ability to use HF ultrasound elastography to distinguish different SWVs of hand tendons. The SWVs were 0.73 ± 0.65 m/s and 1 ± 0.54 m/s for flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP), respectively, and 0.52 ± 0.14 m/s and 4.02 ± 0.77 m/s for extensor tendon under stretch and contraction conditions, respectively. The simplicity and convenience of the HF ultrasound elastography system for measuring hand tendon stiffness make it a promising tool for evaluating the severity of hand injuries and the performance of rehabilitation after hand injuries.

Entities:  

Mesh:

Year:  2019        PMID: 31478846     DOI: 10.1109/TUFFC.2019.2938147

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  2 in total

Review 1.  Ultrasonic technologies in imaging and drug delivery.

Authors:  Yi-Ju Ho; Chih-Chung Huang; Ching-Hsiang Fan; Hao-Li Liu; Chih-Kuang Yeh
Journal:  Cell Mol Life Sci       Date:  2021-07-23       Impact factor: 9.261

2.  High-Frequency Ultrasound Elastography to Assess the Nonlinear Elastic Properties of the Cornea and Ciliary Body.

Authors:  Junhang Zhang; Javier Murgoitio-Esandi; Xuejun Qian; Runze Li; Chen Gong; Amir Nankali; Liang Hao; Benjamin Y Xu; K Kirk Shung; Assad Oberai; Qifa Zhou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-08-26       Impact factor: 3.267

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.