Literature DB >> 31478839

High Resolution ADC for Ultrasound Color Doppler Imaging Based On MASH Sigma-Delta Modulator.

Di Li, Xuejun Qian, Runze Li, Chunlong Fei, Laiming Jiang, Xuyuan Chen, Yintang Yang, Qifa Zhou.   

Abstract

OBJECTIVE: A high precision quantization ultrasound imaging system, capable of capturing small variances of the echo signal with a wide dynamic range, is important for producing accurate diagnostic outputs. Commercial ultrasound systems, typically utilizing 12 or 14 bits analog-to-digital converters (ADCs), lack the ability to measure blood flow deep inside the tissue and may be affected by surrounding tissue noise.
METHODS: In this study, we propose a newly designed ADC with over 20-bit resolution. The superior performance was achieved by shaping the quantization noise with a [Formula: see text] sigma-delta modulator (SDM), and filtering the shaped noise at high frequencies by a digital decimation filter.
RESULTS: Designed in a mature 0.35 μm CMOS technology and powered by a 3.3 V voltage supply, the proposed SDM integrated circuits (IC) model achieved a signal to noise and distortion ratio (SNDR) of 109.5 dB, and an effective number of bits (ENOB) of 17.9-bit in an 8 MHz bandwidth. Eight identical SDMs were integrated onto one chip, and the entire layout occupied an area of 4.8 mm × 5 mm. A total of sixteen 8-channel SDM IC models were connected to all elements of the array transducer.
CONCLUSION: Simulated performance with blood flow evaluation datasets using 12-bit and 20-bit ADCs demonstrates that the proposed 20-bit ADC provides superior overall performance on image contrast and estimation accuracy of the blood speed. SIGNIFICANCE: Owing to these advantages, the 20-bit ADC shows promise for future development of ultrasound imaging systems, especially for color Doppler imaging.

Year:  2019        PMID: 31478839     DOI: 10.1109/TBME.2019.2938275

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

1.  Application of Color Doppler Ultrasound in Microscopic Imaging Diagnosis of Adenomyosis.

Authors:  Jianchang Zhu; Shuang Liu; Dandan Gao
Journal:  Scanning       Date:  2022-05-31       Impact factor: 1.750

2.  A Low Power Sigma-Delta Modulator with Hybrid Architecture.

Authors:  Shengbiao An; Shuang Xia; Yue Ma; Arfan Ghani; Chan Hwang See; Raed A Abd-Alhameed; Chuanfeng Niu; Ruixia Yang
Journal:  Sensors (Basel)       Date:  2020-09-16       Impact factor: 3.576

3.  Application of Color Doppler Ultrasound Combined with Magnetic Resonance Imaging in Placenta Accreta.

Authors:  Xue Sun; Runrun Ren; Xiaoqian Yu; Fang Peng; Xia Gao
Journal:  Scanning       Date:  2022-07-13       Impact factor: 1.750

Review 4.  A Survey on Analog-to-Digital Converter Integrated Circuits for Miniaturized High Resolution Ultrasonic Imaging System.

Authors:  Dongdong Chen; Xinhui Cui; Qidong Zhang; Di Li; Wenyang Cheng; Chunlong Fei; Yintang Yang
Journal:  Micromachines (Basel)       Date:  2022-01-11       Impact factor: 2.891

  4 in total