Orbital floor symmetry after maxillectomy and orbital floor reconstruction with individual titanium mesh using computer-assisted navigation.

Yi-Fan Kang1, Jie Liang1, Zheng He1, Lei Zhang1, Xiao-Feng Shan2, Zhi-Gang Cai3.   

Abstract

PURPOSE: The present study aimed to evaluate the symmetry of the orbital floor after maxillectomy and orbital floor reconstruction with individual titanium mesh using a computer-assisted navigation system. PATIENTS AND METHODS: Nineteen patients who underwent orbital floor reconstruction with individual titanium mesh were included in this study. Postoperative computed tomography scans recorded after three-dimensional (3D) reconstruction were used to evaluate the symmetry of the orbital floor, including orbital floor height, orbital floor eminence, globe projection, orbital volume, and surface deviation.
RESULTS: The average orbital floor height of the reconstructed and the unaffected side was 37.7 ± 2.3 and 37.8 ± 2.7 mm, respectively (P = .47). The average orbital floor eminence of the reconstructed and the unaffected side was 40.1 ± 5.5 and 39.6 ± 5.3 mm, respectively (P = .17). The average globe projection of the reconstructed and the unaffected side was 15.5 ± 3.2 and 15.3 ± 3.0 mm, respectively (P = .27). The average orbital volume of the reconstructed and the unaffected side was 25.9 ± 4.4 and 26.3 ± 4.4 cm3, respectively (P = .29). Repeatability between the reconstructed and the unaffected side was 88.3% ± 2.6% at within 1 mm and 98.6% ± 0.9% at within 2 mm. The average of maximum deviation was 2.4 ± 0.2 mm.
CONCLUSION: Individual titanium mesh is one of the best techniques for orbital floor reconstruction, as it can be placed precisely and helps achieve desirable esthetic outcomes through virtual surgical planning and using a computer-assisted navigation system.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Computed-assisted navigation; Individual titanium mesh; Maxillary reconstruction; Orbital reconstruction; Symmetry

Year:  2019        PMID: 31477492     DOI: 10.1016/j.bjps.2019.07.014

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  1 in total

1.  Virtual Surgical Planning of Deep Circumflex Iliac Artery Flap for Midface Reconstruction.

Authors:  Yi-Fan Kang; Xiao-Ming Lv; Shi-Yu Qiu; Meng-Kun Ding; Shang Xie; Lei Zhang; Zhi-Gang Cai; Xiao-Feng Shan
Journal:  Front Oncol       Date:  2021-09-02       Impact factor: 6.244

  1 in total