Literature DB >> 3147328

Contrast media and glomerular filtration: dose dependence of clearance for three agents.

S E Bäck1, E Krutzén, P Nilsson-Ehle.   

Abstract

Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [51Cr]EDTA in two groups of patients with reduced renal function. When compared with [51Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3147328     DOI: 10.1002/jps.2600770909

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  3 in total

Review 1.  An overview of the clinical pharmacokinetics of x-ray contrast media.

Authors:  M Bourin; P Jolliet; F Ballereau
Journal:  Clin Pharmacokinet       Date:  1997-03       Impact factor: 6.447

2.  Iohexol Clearance for the Determination of Glomerular Filtration Rate: 15 Years' Experience in Clinical Practice.

Authors:  Peter Nilsson-Ehle
Journal:  EJIFCC       Date:  2001-07-22

3.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Natalie Ebert; Toralf Melsom; Flavio Gaspari; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Sten-Erik Bäck
Journal:  Clin Kidney J       Date:  2016-08-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.