Literature DB >> 31472632

Rapid and high-precision sizing of single particles using parallel suspended microchannel resonator arrays and deconvolution.

Max A Stockslager1, Selim Olcum2, Scott M Knudsen2, Robert J Kimmerling3, Nathan Cermak4, Kristofor R Payer5, Vincent Agache6, Scott R Manalis1.   

Abstract

Measuring the size of micron-scale particles plays a central role in the biological sciences and in a wide range of industrial processes. A variety of size parameters, such as particle diameter, volume, and mass, can be measured using electrical and optical techniques. Suspended microchannel resonators (SMRs) are microfluidic devices that directly measure particle mass by detecting a shift in resonance frequency as particles flow through a resonating microcantilever beam. While these devices offer high precision for sizing particles by mass, throughput is fundamentally limited by the small dimensions of the resonator and the limited bandwidth with which changes in resonance frequency can be tracked. Here, we introduce two complementary technical advancements that vastly increase the throughput of SMRs. First, we describe a deconvolution-based approach for extracting mass measurements from resonance frequency data, which allows an SMR to accurately measure a particle's mass approximately 16-fold faster than previously possible, increasing throughput from 120 particles/min to 2000 particles/min for our devices. Second, we describe the design and operation of new devices containing up to 16 SMRs connected fluidically in parallel and operated simultaneously on the same chip, increasing throughput to approximately 6800 particles/min without significantly degrading precision. Finally, we estimate that future systems designed to combine both of these techniques could increase throughput by nearly 200-fold compared to previously described SMR devices, with throughput potentially as high as 24 000 particles/min. We envision that increasing the throughput of SMRs will broaden the range of applications for which mass-based particle sizing can be employed.

Entities:  

Year:  2019        PMID: 31472632      PMCID: PMC6716975          DOI: 10.1063/1.5100861

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  5 in total

Review 1.  Cellular and biomolecular detection based on suspended microchannel resonators.

Authors:  Juhee Ko; Jaewoo Jeong; Sukbom Son; Jungchul Lee
Journal:  Biomed Eng Lett       Date:  2021-09-12

2.  Simple and Robust Microfabrication of Polymeric Piezoelectric Resonating MEMS Mass Sensors.

Authors:  Chang Ge; Edmond Cretu
Journal:  Sensors (Basel)       Date:  2022-04-13       Impact factor: 3.847

3.  Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting.

Authors:  Wilson Ombati Nyang'au; Andi Setiono; Angelika Schmidt; Harald Bosse; Erwin Peiner
Journal:  Sensors (Basel)       Date:  2020-04-28       Impact factor: 3.576

4.  A V-Shaped Microcantilever Sensor Based on a Gap Method for Real-Time Detection of E. coli Bacteria.

Authors:  Jino Fathy; Yongjun Lai
Journal:  Biosensors (Basel)       Date:  2022-03-25

Review 5.  Fabricating Silicon Resonators for Analysing Biological Samples.

Authors:  Momoko Kumemura; Deniz Pekin; Vivek Anand Menon; Isabelle Van Seuningen; Dominique Collard; Mehmet Cagatay Tarhan
Journal:  Micromachines (Basel)       Date:  2021-12-12       Impact factor: 2.891

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.