Literature DB >> 31470126

SpinDoctor: A MATLAB toolbox for diffusion MRI simulation.

Jing-Rebecca Li1, Van-Dang Nguyen2, Try Nguyen Tran3, Jan Valdman4, Cong-Bang Trang3, Khieu Van Nguyen3, Duc Thach Son Vu3, Hoang An Tran3, Hoang Trong An Tran3, Thi Minh Phuong Nguyen3.   

Abstract

The complex transverse water proton magnetization subject to diffusion-encoding magnetic field gradient pulses in a heterogeneous medium can be modeled by the multiple compartment Bloch-Torrey partial differential equation. Under the assumption of negligible water exchange between compartments, the time-dependent apparent diffusion coefficient can be directly computed from the solution of a diffusion equation subject to a time-dependent Neumann boundary condition. This paper describes a publicly available MATLAB toolbox called SpinDoctor that can be used 1) to solve the Bloch-Torrey partial differential equation in order to simulate the diffusion magnetic resonance imaging signal; 2) to solve a diffusion partial differential equation to obtain directly the apparent diffusion coefficient; 3) to compare the simulated apparent diffusion coefficient with a short-time approximation formula. The partial differential equations are solved by P1 finite elements combined with built-in MATLAB routines for solving ordinary differential equations. The finite element mesh generation is performed using an external package called Tetgen. SpinDoctor provides built-in options of including 1) spherical cells with a nucleus; 2) cylindrical cells with a myelin layer; 3) an extra-cellular space enclosed either a) in a box or b) in a tight wrapping around the cells; 4) deformation of canonical cells by bending and twisting; 5) permeable membranes; Built-in diffusion-encoding pulse sequences include the Pulsed Gradient Spin Echo and the Oscillating Gradient Spin Echo. We describe in detail how to use the SpinDoctor toolbox. We validate SpinDoctor simulations using reference signals computed by the Matrix Formalism method. We compare the accuracy and computational time of SpinDoctor simulations with Monte-Carlo simulations and show significant speed-up of SpinDoctor over Monte-Carlo simulations in complex geometries. We also illustrate several extensions of SpinDoctor functionalities, including the incorporation of T2 relaxation, the simulation of non-standard diffusion-encoding sequences, as well as the use of externally generated geometrical meshes.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Apparent diffusion coefficient; Bloch-torrey equation; Diffusion magnetic resonance imaging; Finite elements; Simulation

Year:  2019        PMID: 31470126     DOI: 10.1016/j.neuroimage.2019.116120

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  1 in total

Review 1.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.