Literature DB >> 31468306

Design a prototype for automated patient diagnosis in wireless sensor networks.

Ayyasamy Ayyanar1, Maruthavanan Archana1, Y Harold Robinson2, E Golden Julie3, Raghvendra Kumar4, Le Hoang Son5,6.   

Abstract

It is indeed necessary to design of an elderly support mobile healthcare and monitoring system on wireless sensor network (WSN) for dynamic monitoring. It comes from the need for maintenance of healthcare among patients and elderly people that leads to the demand on change in traditional monitoring approaches among chronic disease patients and alert on acute events. In this paper, we propose a new automated patient diagnosis called automated patient diagnosis (AUPA) using ATmega microcontrollers over environmental sensors. AUPA monitors and aggregates data from patients through network connected over web server and mobile network. The scheme supports variable data management and route establishment. Data transfer is established using adaptive route discovery and management approaches. AUPA supports minimizing packet loss and delay, handling erroneous data, and providing optimized decision-making for healthcare support. The performance of AUPA's QoS approach is tested using a set of health-related sensors which gather the patient's data over variable period of time and send from a source to destination AUPA node. Experimental results show that AUPA outperforms the existing schemes, namely SPIN and LEACH, with minimal signal loss rate and a better neighborhood node selection and link selection. It diminishes the jitter compared to the related algorithms. Graphical abstract Stack architecture of AUPA.

Entities:  

Keywords:  AUPA; Microcontroller; QoS; Route management; Sensors; WSN

Mesh:

Year:  2019        PMID: 31468306     DOI: 10.1007/s11517-019-02036-4

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  8 in total

1.  ECG-cryptography and authentication in body area networks.

Authors:  Zhaoyang Zhang; Honggang Wang; Athanasios V Vasilakos; Hua Fang
Journal:  IEEE Trans Inf Technol Biomed       Date:  2012-06-26

2.  A wrist sensor and algorithm to determine instantaneous walking cadence and speed in daily life walking.

Authors:  Benedikt Fasel; Cyntia Duc; Farzin Dadashi; Flavien Bardyn; Martin Savary; Pierre-André Farine; Kamiar Aminian
Journal:  Med Biol Eng Comput       Date:  2017-02-14       Impact factor: 2.602

3.  Decision Making Based on Fuzzy Aggregation Operators for Medical Diagnosis from Dental X-ray images.

Authors:  Tran Thi Ngan; Tran Manh Tuan; Le Hoang Son; Nguyen Hai Minh; Nilanjan Dey
Journal:  J Med Syst       Date:  2016-10-27       Impact factor: 4.460

4.  Logic-centered architecture for ubiquitous health monitoring.

Authors:  Jacek Lewandowski; Hisbel E Arochena; Raouf N G Naguib; Kuo-Ming Chao; Alexeis Garcia-Perez
Journal:  IEEE J Biomed Health Inform       Date:  2014-09       Impact factor: 5.772

5.  Design and test of a Microsoft Kinect-based system for delivering adaptive visual feedback to stroke patients during training of upper limb movement.

Authors:  Daniel Simonsen; Mirjana B Popovic; Erika G Spaich; Ole Kæseler Andersen
Journal:  Med Biol Eng Comput       Date:  2017-03-25       Impact factor: 2.602

6.  Modeling and development of screen-printed impedance biosensor for cytotoxicity studies of lung carcinoma cells.

Authors:  Ahmad Fairuzabadi Mohd Mansor; Irmanisha Ibrahim; Ahmad Anwar Zainuddin; Ioana Voiculescu; Anis Nurashikin Nordin
Journal:  Med Biol Eng Comput       Date:  2017-12-16       Impact factor: 2.602

7.  A method to qualitatively assess arm use in stroke survivors in the home environment.

Authors:  Kaspar Leuenberger; Roman Gonzenbach; Susanne Wachter; Andreas Luft; Roger Gassert
Journal:  Med Biol Eng Comput       Date:  2016-04-22       Impact factor: 2.602

8.  IoT Based Heart Activity Monitoring Using Inductive Sensors.

Authors:  Adrian Brezulianu; Oana Geman; Marius Dan Zbancioc; Marius Hagan; Cristian Aghion; D Jude Hemanth; Le Hoang Son
Journal:  Sensors (Basel)       Date:  2019-07-26       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.