Literature DB >> 31464856

Effect of Nail Size, Insertion, and Δ Canal-Nail on the Development of a Nonunion After Intramedullary Nailing of Femoral Shaft Fractures.

Rafael Serrano1, Hassan R Mir2, R Allen Gorman3, Jordan Karsch1, Ryan Kim1, Anjan Shah2, Benjamin Maxson2, Anthony Infante2, David Watson2, Katheryne Downes2, Roy W Sanders2.   

Abstract

OBJECTIVE: To determine whether intramedullary nail (IMN) diameter, antegrade versus retrograde insertion, or the difference between the canal and IMN diameter affect femoral shaft fracture healing.
DESIGN: Retrospective analysis of a prospective database.
SETTING: Level One Regional Trauma Center. PATIENTS/PARTICIPANTS: Seven hundred thirty-three femoral shaft fractures (OTA/AO 32) treated with an IMN between 1999 and 2017. After exclusion criteria, 484 fractures remained in the final analysis. INTERVENTION: Closed section, cannulated, interlocked, titanium alloy IMN using a reamed insertion technique. MAIN OUTCOME MEASUREMENTS: Nonunion, IMN size (10, 11.5, and 13 mm), antegrade versus retrograde insertion, Δ canal-nail diameter (ΔD) after reaming (<1, 1-2, or >2 mm).
RESULTS: IMN diameters used were as follows: 314/10 mm (64%), 137/11.5 mm (28%), and 33/13 mm (8%). Forty-five percent were placed in antegrade versus 55% retrograde. Four hundred fifty-six fractures (94.2%) healed uneventfully. There were no IMN failures. 10/484 IMNs (2%) had broken interlocking screws; only 4 were associated with a NU. Average time to union was 23 weeks (12-119). Twenty-eight (5.8%) developed NU. There was no statistical correlation between (1) the NU rate and IMN diameter: 10 mm, 6.3%; 11.5 mm, 5.1%; 13 mm, 3% (P = 0.8, power = 0.85), (2) the NU rate and ΔD: 7.1% <1 mm, 5.6% 1-2 mm, 20% >2 mm (P = 0.36), (3) the NU rate and fracture location: Prox = 11%, Mid = 5%, Dist = 3% (P = 0.13), or (4) the NU rate and antegrade (7.2%) versus retrograde (4.2%) insertion (P = 0.24).
CONCLUSION: Similar healing rates occurred regardless of IMN diameter, Δ canal-nail diameter after reaming, or insertion site. This indicates that a closed section, cannulated, interlocked, titanium alloy IMN with a diameter of 10 mm can be considered the standard diameter for the treatment of acute femoral shaft fractures, regardless of entry point. This should be associated with less reaming and therefore shorter operative times, and possibly less hospital implant inventories as well. Larger diameter IMN should be reserved for revision surgery. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

Entities:  

Year:  2019        PMID: 31464856     DOI: 10.1097/BOT.0000000000001585

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  5 in total

Review 1.  Fatigue Crack Growth and Fracture of Internal Fixation Materials in In Vivo Environments-A Review.

Authors:  Kailun Wu; Bin Li; Jiong Jiong Guo
Journal:  Materials (Basel)       Date:  2021-01-01       Impact factor: 3.623

2.  Weight-bearing status may influence rates of radiographic healing following reamed, intramedullary fixation of diaphyseal femur fractures.

Authors:  Christopher D Flanagan; Noah M Joseph; Jonathan Copp; Nicholas Romeo; Nicholas Alfonso; Adam Hirschfeld
Journal:  OTA Int       Date:  2021-10-01

3.  Aseptic femoral nonunion treated with exchange locked nailing with intramedullary augmentation cancellous bone graft.

Authors:  Chi-Chuan Wu
Journal:  J Orthop Surg Res       Date:  2022-07-06       Impact factor: 2.677

4.  The Butterfly Fragment in Wedge-Shaped Femoral Shaft Fracture: Comparison of Two Different Surgical Methods.

Authors:  Yuan-Hsin Tsai; Teng-Kuan Wang; Pei-Yuan Lee; Chih-Hui Chen
Journal:  Orthop Surg       Date:  2022-06-22       Impact factor: 2.279

5.  Does nail size or difference between canal and nail diameter influence likelihood of union or time to union of femoral shaft fractures treated with intramedullary nailing? A retrospective cohort study.

Authors:  Chiu-Yu Shih; Chew-Teng Kor; Cheng-Pu Hsieh; Chiu-Liang Chen; Yu-Cheng Lo
Journal:  BMC Musculoskelet Disord       Date:  2022-08-31       Impact factor: 2.562

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.