Literature DB >> 31461392

Bonding Performance of Universal Adhesive Systems Applied in Etch-and-Rinse and Self-Etch Strategies on Natural Dentin Caries.

V Hass, Afm Cardenas, Fsf Siqueira, R R Pacheco, Pmw Zago, D O Silva, M C Bandeca, A D Loguercio.   

Abstract

OBJECTIVE: This study investigated the bonding performance of three universal adhesive systems applied using etch-and-rinse (ER) or self-etch (SE) strategies on natural dentin caries.
MATERIALS AND METHODS: Sixty human third molars were selected for this study: 30 naturally carious (CAD) and 30 sound (SD) teeth. The dentin surfaces were exposed, and teeth were randomly assigned to each evaluated adhesive system: Scotchbond Universal (SBU), Futurabond U (FBU), and Prime&Bond Elect (PBE) and an adhesive strategy: ER or SE. The adhesive systems were applied following the manufacturer's instructions, and the teeth were restored using a resin composite (Filtek Supreme Ultra, 3M). After 24 hours (distilled water at 37°C), samples were sectioned and evaluated using microtensile bond strength analysis (μTBS), micro-Raman spectroscopy to evaluate the degree of conversion within the hybrid layer (DC), and scanning electronic microscopy (SEM) to describe the morphology of the hybrid layer. The μTBS and DC data were analyzed using three-way analysis of variance and Tukey's test for means comparison (α=0.05). The SEM images were analyzed qualitatively.
RESULTS: Reduced μTBS values were observed when comparing CAD with SD, regardless of adhesive system or strategy (p<0.0001). SBU showed statistically higher μTBS for both dentin substrates and strategies (p<0.0001). Furthermore, SBU showed greater integrity of the hybrid layer and resin tag formation compared with FBU and PBE. Mean μTBS values for FBU were higher for SD in the SE mode, whereas higher mean μTBS values were observed for CAD in the ER mode, both compared with PBE (p<0.001).
CONCLUSION: Bonding performance is reduced on a caries-affected substrate. The ER strategy was not able to improve the bonding performance on natural CAD for universal adhesive systems. Improved bonding performance was obtained when using the Scotchbond Universal system.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31461392     DOI: 10.2341/17-252-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  3 in total

1.  Bonding effects of cleaning protocols and time-point of acid etching on dentin impregnated with endodontic sealer.

Authors:  Tatiane Miranda Manzoli; Joissi Ferrari Zaniboni; João Felipe Besegato; Flávia Angélica Guiotti; Andréa Abi Rached Dantas; Milton Carlos Kuga
Journal:  Restor Dent Endod       Date:  2022-04-06

2.  Is it possible for a simultaneous biomodification during acid etching on naturally caries-affected dentin bonding?

Authors:  Viviane Hass; Thais Bezerra da Maceno Oliveira; Andrés Felipe Millan Cardenas; Fabiana Suelen Figueredo de Siqueira; Jose Roberto Bauer; Gabriel Abuna; Mario Alexandre Coelho Sinhoreti; Jullian Josnei de Souza; Alessandro D Loguercio
Journal:  Clin Oral Investig       Date:  2020-11-16       Impact factor: 3.573

Review 3.  Raman Spectroscopy: A Potential Diagnostic Tool for Oral Diseases.

Authors:  Yuwei Zhang; Liang Ren; Qi Wang; Zhining Wen; Chengcheng Liu; Yi Ding
Journal:  Front Cell Infect Microbiol       Date:  2022-02-04       Impact factor: 5.293

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.