| Literature DB >> 31455421 |
Claudia Brusasco1, Gregorio Santori2, Elisa Bruzzo3, Rosella Trò3, Chiara Robba4, Guido Tavazzi5, Fabio Guarracino6, Francesco Forfori7, Patrizia Boccacci3, Francesco Corradi8,9.
Abstract
BACKGROUND: This pilot study was designed to develop a fully automatic and quantitative scoring system of B-lines (QLUSS: quantitative lung ultrasound score) involving the pleural line and to compare it with previously described semi-quantitative scores in the measurement of extravascular lung water as determined by standard thermo-dilution.Entities:
Keywords: Acute respiratory distress syndrome; Computer-aided diagnosis; Extravascular lung water; Lung ultrasound; Pulmonary edema
Mesh:
Year: 2019 PMID: 31455421 PMCID: PMC6712728 DOI: 10.1186/s13054-019-2569-4
Source DB: PubMed Journal: Crit Care ISSN: 1364-8535 Impact factor: 9.097
Fig. 1Segmentation algorithm basic steps. Upper left: sub-pleural selection from the original ultrasound scan. Upper right: K-means classification to divide pixels into two subsets. Bottom right: alternated sequential filter consisting in iterative morphological openings and closings, with an axial-line structuring element which closes small (10-pixel) gaps axially and isolates the objects laterally, thus enhancing the B-line contours. Bottom left: B-line detection scanning the images along their columns selecting those with ≥ 50% of white pixels over 70% of their total vertical length
The LUS scores and the EVLW values for each patient enrolled in this study
| Patients | QLUSS | qLUSS | %LUSS | cLUSS | nLUSS | EVLW (mL/kg) |
|---|---|---|---|---|---|---|
| 1 | 2.26 | 9 | 16 | 14 | 23 | 8.00 |
| 2 | 15.72 | 12 | 27 | 24 | 19 | 10.00 |
| 3 | 31.31 | 18 | 38 | 24 | 14 | 17.00 |
| 4 | 15.00 | 9 | 16 | 18 | 16 | 10.00 |
| 5 | 22.24 | 12 | 26 | 22 | 35 | 12.00 |
| 6 | 28.19 | 14 | 44 | 24 | 29 | 16.00 |
| 7 | 25.17 | 22 | 46 | 26 | 23 | 20.70 |
| 8 | 37.66 | 14 | 25 | 17 | 19 | 14.00 |
| 9 | 13.46 | 11 | 13 | 14 | 9 | 11.70 |
| 10 | 22.21 | 9 | 36 | 13 | 24 | 12.00 |
| 11 | 10.15 | 9 | 12 | 11 | 28 | 8.00 |
| 12 | 10.55 | 12 | 11 | 20 | 14 | 10.00 |
Fig. 2Simple linear regression models by entering the semi-quantitative scores [B-line coalescence score (cLUSS), modified B-line coalescence score (qLUSS), percentage of lung area occupied by B-lines (%LUSS), maximum number of B-lines (nLUSS)] and quantitative computer-aided score (QLUSS) for evaluating their association with extravascular lung water (EVLW). a QLUSS~EVLW (p = 0.005). b cLUSS~EVLW (p = 0.016). c qLUSS~EVLW (p < 0.001). d %LUSS~EVLW (p < 0.001). e nLUSS~EVLW (p = 0.956)
Fig. 3Correlations of computer-aided score (QLUSS) with semi-quantitative scores [maximum number of B-lines (nLUSS), visual percentage of lung area occupied by B-lines (%LUSS), B-line coalescence score (cLUSS), modified B-line coalescence score (qLUSS)] in 12 mechanically ventilated patients
Fig. 4Left: involvement of about half of the pleural line, difficult to be objectively quantified by the eye. Right: computer-aided QLUSS showing an involvement of the pleural line by 40%