Literature DB >> 31450472

Paper-based cascade cationic isotachophoresis: Multiplex detection of cardiac markers.

Shuang Guo1, William Schlecht1, Lei Li2, Wen-Ji Dong3.   

Abstract

Paper-based analytical devices (PADs) are widely used in point-of-care testing (POCT) as they are cost-effective, simple and straightforward. However, poor sensitivity hinders their use in detecting diseases with low abundance biomarkers. The poor detection limit of PADs is mainly attributed to the low concentration of analytes, and the complexity of biological fluid, leading to insufficient interactions between analytes and capture antibodies. This study aims to overcome these difficulties by developing a paper-based cationic isotachophoresis (ITP) approach for simultaneously detecting pico-molar levels of two essential cardiac protein markers: acidic troponin T (cTnT) and basic troponin I (cTnI) spiked into human serum samples. The approach utilizes 3-aminopropyltrimethoxysilane (APTMS) treated glass fiber papers with decreasing cross-sectional area assembled on a 3D printed cartridge device. Our results showed that in the presence of cTnT monoclonal antibody (mAb), fluorescently labeled cTnI and cTnT could be effectively enriched in cationic ITP. Each individual target was captured subsequently by a test line in the detection zone where the capture mAb was immobilized. Detailed analysis suggests that the technology is capable of simultaneous on-board depletion of abundant plasma proteins and enrichment of cTnI/cTnT by ~1300-fold with a sensitivity of 0.6 pmol/L for cTnT and a sensitivity of 1.5 pmol/L for cTnI in less than 6 min. The results demonstrate the potential of this technology for rapid, ultra-sensitive and cost-effective analysis of multiplex protein markers in clinical serum samples at point of care.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Isotachophoresis; Paper-based analytical devices; Point of care testing; Troponin

Year:  2019        PMID: 31450472      PMCID: PMC6858795          DOI: 10.1016/j.talanta.2019.07.007

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  46 in total

Review 1.  The human plasma proteome: history, character, and diagnostic prospects.

Authors:  N Leigh Anderson; Norman G Anderson
Journal:  Mol Cell Proteomics       Date:  2002-11       Impact factor: 5.911

2.  THE EFFECT OF PH AND IONIC STRENGTH ON THE REACTION BETWEEN ANTI-D AND ERYTHROCYTES.

Authors:  N C HUGHES-JONES; B GARDNER; R TELFORD
Journal:  Immunology       Date:  1964-01       Impact factor: 7.397

3.  Effects of PKA phosphorylation of cardiac troponin I and strong crossbridge on conformational transitions of the N-domain of cardiac troponin C in regulated thin filaments.

Authors:  Wen-Ji Dong; Jayant James Jayasundar; Jianli An; Jun Xing; Herbert C Cheung
Journal:  Biochemistry       Date:  2007-08-03       Impact factor: 3.162

4.  Limit of blank, limit of detection and limit of quantitation.

Authors:  David A Armbruster; Terry Pry
Journal:  Clin Biochem Rev       Date:  2008-08

5.  Two orders of magnitude improvement in detection limit of lateral flow assays using isotachophoresis.

Authors:  Babak Y Moghadam; Kelly T Connelly; Jonathan D Posner
Journal:  Anal Chem       Date:  2015-01-07       Impact factor: 6.986

6.  The specificity of pH and ionic strength effects on the kinetics of the Rh (D)-anti-Rh (D) system.

Authors:  A E Barnes
Journal:  J Immunol       Date:  1966-05       Impact factor: 5.422

7.  Sample pre-concentration with high enrichment factors at a fixed location in paper-based microfluidic devices.

Authors:  Shih-Hao Yeh; Kuang-Hua Chou; Ruey-Jen Yang
Journal:  Lab Chip       Date:  2016-03-07       Impact factor: 6.799

8.  Quantification of cardiac troponin I in human plasma by immunoaffinity enrichment and targeted mass spectrometry.

Authors:  Nicole A Schneck; Karen W Phinney; Sang Bok Lee; Mark S Lowenthal
Journal:  Anal Bioanal Chem       Date:  2018-03-01       Impact factor: 4.142

Review 9.  Analytical characteristics of high-sensitivity cardiac troponin assays.

Authors:  Fred S Apple; Paul O Collinson
Journal:  Clin Chem       Date:  2011-09-30       Impact factor: 8.327

Review 10.  Drivers of biodiagnostic development.

Authors:  David A Giljohann; Chad A Mirkin
Journal:  Nature       Date:  2009-11-26       Impact factor: 49.962

View more
  3 in total

Review 1.  Isotachophoresis: Theory and Microfluidic Applications.

Authors:  Ashwin Ramachandran; Juan G Santiago
Journal:  Chem Rev       Date:  2022-06-22       Impact factor: 72.087

Review 2.  Lab-on-a-Chip Devices for Point-of-Care Medical Diagnostics.

Authors:  Sofia Arshavsky-Graham; Ester Segal
Journal:  Adv Biochem Eng Biotechnol       Date:  2022       Impact factor: 2.768

Review 3.  Recent Advances in Microfluidic Devices for Contamination Detection and Quality Inspection of Milk.

Authors:  Hwee-Yeong Ng; Wen-Chin Lee; Chia-Te Kung; Lung-Chih Li; Chien-Te Lee; Lung-Ming Fu
Journal:  Micromachines (Basel)       Date:  2021-05-14       Impact factor: 2.891

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.