Literature DB >> 31446868

External contamination of antineoplastic drug containers from a Canadian wholesaler.

D Hilliquin1, J F Bussières1,2.   

Abstract

INTRODUCTION: Contamination of hospitals' surfaces with antineoplastic drugs is documented despite safe handling practices. The exterior of commercial containers is often contaminated during the manufacturing process and can cross-contaminate hospitals' surfaces. The aim was to investigate the contamination of the exterior of antineoplastic drug vials available in Canada in 2018.
METHODS: Cross-sectional study. All available antineoplastic drugs vials from a single wholesaler were targeted. Containers were sampled upon their receipt by the pharmacy staff, before they were cleaned. One wipe was used to sample the external surface of five vials from a single batch from the same manufacturer. Nine antineoplastic drugs were quantified by ultra-performance liquid chromatography-tandem mass spectrometer: cyclophosphamide, docetaxel, 5-fluorouracil, gemcitabine, ifosfamide, irinotecan, methotrexate, paclitaxel, vinorelbine.
RESULTS: Twenty-one samplings were done (105 containers from nine different manufacturers): cyclophosphamide = 2, docetaxel = 1, gemcitabine = 2, 5-fluorouracil = 2, ifosfamide = 2, irinotecan = 3, methotrexate = 6, paclitaxel = 2, vinorelbine = 1. One of these samplings was done on blister packaging, the remainder were done on glass vials. A total of 15/21 samples (71%) were positive to at least one drug (docetaxel, 5-fluorouracil, ifosfamide, and vinorelbine). A maximum of 272 ng/vial was quantified (gemcitabine). Cross contamination with other antineoplastic drugs was detected on 16/21 (76%) samples.
CONCLUSION: The majority of samples were positive to at least one antineoplastic drug, confirming that the exterior of antineoplastic drugs containers is still an important source of contamination. Manufacturers should reduce this contamination. Vials should be washed upon receipt, before they are stored in pharmacy. Gloves must be worn at all times to avoid occupational exposure.

Entities:  

Keywords:  Antineoplastic drugs; environmental surveillance; hazardous drugs; occupational exposure

Mesh:

Substances:

Year:  2019        PMID: 31446868     DOI: 10.1177/1078155219868525

Source DB:  PubMed          Journal:  J Oncol Pharm Pract        ISSN: 1078-1552            Impact factor:   1.809


  1 in total

1.  Evaluation of external contamination on the vial surfaces of some hazardous drugs that commonly used in Chinese hospitals and comparison between environmental contamination generated during robotic compounding by IV: Dispensing robot vs. manual compounding in biological safety cabinet.

Authors:  Hao Ml; Wang T; Zhu Jq; Song Yj; Gong Tj; Zou Lk; Liu J; Yan Jf
Journal:  J Oncol Pharm Pract       Date:  2021-06-24       Impact factor: 1.416

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.