Literature DB >> 31445806

Losses of poly- and perfluoroalkyl substances to syringe filter materials.

Mattias Sörengård1, Vera Franke2, Rikard Tröger2, Lutz Ahrens2.   

Abstract

Syringe filters are used to separate solids from liquids prior to analysis of poly- and perfluoroalkyl substances (PFASs). This is a critical step in sample preparation, as losses of PFASs to the filter material can be significant and lead to underestimation. This study evaluated losses of 21 PFASs in three different matrices (methanol, MilliQ water, and water containing 10 mg L-1 dissolved organic carbon (DOC)) to six different types of syringe filter (0.45 and 0.22 μm). Regarding sample matrix, the lowest average ∑21PFAS losses were observed in methanol (13%), followed by DOC water (19%) and MilliQ water (26%). Regarding syringe filter material, the lowest average losses of ∑21PFAS in DOC water and MilliQ water were observed for a recycled cellulose filter (average losses 16% and 21%, respectively), while a polypropylene filter had the lowest ∑21PFAS losses in methanol (9%). A smaller polyethersulfone (PES) filter (0.22 μm, 17 mm Ø) showed significantly (p < 0.05) lower ∑21PFAS losses in DOC water (on average 7.3%) than a larger PES filter (0.45 μm, 37 mm Ø) (23%). In DOC water, losses to the filter increased by 3.8%, 5.1%, and 8.4% per CF2-moiety for C3-C11 perfluoroalkyl carboxylates (PFCAs), perfluoroalkyl sulfonates (PFSAs), and fluorotelomer sulfonic acids (FTSAs), respectively. Comparing different functional groups of PFASs, losses increased as follows: PFCAs < PFSAs < FTSAs < perfluorooctanesulfonamides (FOSAs). Thus, care is needed when including filtration in PFAS analysis, since losses can be significant (up to 100%) depending on the type of syringe filter, target PFAS, and matrix.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Analysis; Extraction; Filter; Method development; Per- and polyfluoroalkyl substances

Mesh:

Substances:

Year:  2019        PMID: 31445806     DOI: 10.1016/j.chroma.2019.460430

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Analysis of per- and polyfluorinated alkyl substances in sub-sampled water matrices with online solid phase extraction/isotope dilution tandem mass spectrometry.

Authors:  Toby Sanan; Matthew Magnuson
Journal:  J Chromatogr A       Date:  2020-06-07       Impact factor: 4.759

2.  Selectivity of Per- and Polyfluoroalkyl Substance Sensors and Sorbents in Water.

Authors:  Yuqin Wang; Seth B Darling; Junhong Chen
Journal:  ACS Appl Mater Interfaces       Date:  2021-12-15       Impact factor: 9.229

3.  The Adsorption of Per- and Polyfluoroalkyl Substances (PFASs) onto Ferrihydrite Is Governed by Surface Charge.

Authors:  Hugo Campos-Pereira; Dan B Kleja; Carin Sjöstedt; Lutz Ahrens; Wantana Klysubun; Jon Petter Gustafsson
Journal:  Environ Sci Technol       Date:  2020-11-27       Impact factor: 9.028

4.  Direct injection analysis of per and polyfluoroalkyl substances in surface and drinking water by sample filtration and liquid chromatography-tandem mass spectrometry.

Authors:  M Abdul Mottaleb; Qunxing X Ding; Kelly G Pennell; Erin N Haynes; Andrew J Morris
Journal:  J Chromatogr A       Date:  2021-07-21       Impact factor: 4.759

  4 in total