Literature DB >> 31438871

An evaluation of phase angle, bioelectrical impedance vector analysis and impedance ratio for the assessment of disease status in children with nephrotic syndrome.

Steven Brantlov1, Lars Jødal2, René Frydensbjerg Andersen3, Aksel Lange3, Søren Rittig3, Leigh C Ward4.   

Abstract

pan class="abstract_title">BACKGROUND: al">pan class="Disease">Oedema, characterized by accumulation of extracellular water (ECW), is one of the major clinical manifestations in children suffering from nephrotic syndrome (NS). The lack of a simple, inexpensive and harmless method for assessing ECW may be solved by the use of the bioelectrical impedance analysis (BIA) technique. The aims of this study were to examine whether phase angle (PA), bioelectrical impedance vector analysis (BIVA) and the impedance ratio (IR) reflect change in disease status in children with NS.
METHODS: Eight children (age range: 2-10 years) with active NS (ANS group) were enrolled. In five of these (ANS* subgroup), impedance was also measured at remission (NSR group). Thirty-eight healthy children (age range: 2-10 years) were included as healthy controls (HC group). Whole-body impedance was measured with a bioimpedance spectroscopy device (Xitron 4200) with surface electrodes placed on the wrist and ankle.
RESULTS: Values of PA, BIVA and IR were found to be significantly lower (p-value range < 0.001 to < 0.01) in the ANS patients compared to the HC and NSR groups. No significant differences were observed between the NSR and HC groups.
CONCLUSION: The studied parameters can be used to assess change in disease status in NS patients. Data were consistent with NS being associated with expansion of ECW.

Entities:  

Keywords:  Bioelectrical impedance vector analysis; Children; Electrical impedance; Impedance ratio; Nephrotic syndrome; Phase angle; Total body water

Mesh:

Year:  2019        PMID: 31438871      PMCID: PMC6704501          DOI: 10.1186/s12882-019-1511-y

Source DB:  PubMed          Journal:  BMC Nephrol        ISSN: 1471-2369            Impact factor:   2.388


Background

n class="Disease">Nephrotic syndrome (al">pan class="Disease">NS) is a condition in which the kidneys leak large amounts of proteins into the urine, with consequent hypoalbuminemia and oedema formation [1] and thus causes increased risk of complications and prolonged hospitalization [2]. Normally, body weight measurement is used by clinicin class="Chemical">ans as a measure of al">pan class="Disease">oedema, i.e., accumulation of extracellular water (ECW), in NS patients. However, the challenge with this approach is that it is only reliable for short periods of time during which the change in weight due to causes other than water are non-significant [3]. Dilution techniques using the tracers deuterated n class="Chemical">water (al">pan class="Chemical">D2O, “heavy water”) and sodium bromide (NaBr) are the criterion techniques for determining total body water (TBW) and ECW volumes respectively. These are, however, potentially invasive, expensive, time consuming, not possible to repeat at short intervals and require highly trained personnel to make the measurements [4], making them unsuitable for routine use in the clinic [5]. For these reason class="Disease">ns, there is need for a simple, inexpeal">pan class="Disease">nsive and harmless method for routine assessment of disease status that can provide new and clinically useful information to clinicians in the treatment of pediatric NS patients. A possible approach that may prove to be of use is the bioelectrical impedance analysis (BIA) technique, which is characterized by being non-invasive, harmless, quick, simple, inexpensive, and portable and thus suitable for routine use [6]. n class="Chemical">BIA, which is a collective term for bioimpedance devices used to determine body composition [7], is based on the principle that the flow of alternating electrical current through the body varies from tissue to tissue; tissues containing large amounts of al">pan class="Chemical">water and electrolytes have high conductivity, i.e., low impedance, whereas fat and bone have low conductivity and correspondingly high impedance. The impedance of the body is therefore quantitatively (inversely) related to the volume of water in the body. However, a challenge with n class="Chemical">BIA in al">paediatric populatioal">pan class="Disease">ns is that calculation of body water volumes are based on population specific [8, 9] prediction equations that may be inaccurate [10, 11]. Therefore, there is a growing interest in the use of raw impedance data, especially in patients with altered body water distribution [12]. Raw impedance data are not directly linked to body water volumes, but can be considered as indices of such volumes that can vary with sodium and water retention. Of the n class="Chemical">BIA al">parameters using raw impedance data, phase angle (al">pan class="Chemical">PA) is the most commonly used [13]. PA has been linked with body water distribution between the intracellular water (ICW) and ECW spaces (tissue hydration) and cell membrane integrity (amount and quality) in a number of studies [14-16], but the exact biological meaning of the parameter is still not fully understood [13]. Another approach is bioelectrical impedance vector analysis (n class="Chemical">BIVA), which is based on al">pattern analysis of the raw impedance data standardized by the subject’s height, plotted as a al">pan class="Chemical">bivariate vector in a nomogram [17]. This one has gained increased attention in the clinical setting [13], for example with studies conducted in healthy [18] and diseased [19, 20] pediatric populations. A third approach is the impedance ratio (IR), which has been proposed as a potential indicator of n class="Disease">oedema or overall health [12] and as a predictor of mortality in hemodialysis al">pan class="Species">patients [21]. Moreover, IR has been suggested to reflect the fluid distribution between the TBW and the ECW [12]. Until now, few studies using raw impedance data have been performed in adults and none in pediatric populations [12, 22]. The main aim of the present study was to investigate whether n class="Chemical">PA, al">pan class="Chemical">BIVA, and/or IR reflect change in disease status in pediatric patients with NS either active or in remission, and compare to results from healthy children. The BIA parameters are used as indices, while no attempt is made to quantify the fluid volumes. A secondary aim was to determine if there was advantage in using BIA parameters determined at the characteristic frequency, which is considered the optimal frequency for TBW measurement, rather than the conventionally-used 50 kHz.

Methods

The study groups and parameters copan class="Disease">nsidered are summarized in Table 1 and described in the following.
Table 1

Groups and impedance parameters studied in this paper

AbbreviationDescription
ANSChildren with active NS (n = 8)
NSRChildren from ANS group re-studied at time of NS remission (n = 5)
ANS*Subgroup of ANS, same children as NSR group (n = 5)
HCHealthy controls, age-matched to ANS group (n = 38)
HPatient height (m)
f c The characteristic frequency (kHz)
RResistance (Ohm, Ω)
XCCapacitive reactance (Ω)
PA50Phase angle (in degrees) calculated at a frequency of 50 kHz
PAfcPA calculated at fc
BIVARXcBioelectrical impedance vector analysis plot based on R/H and XC/H (unit Ω/m)
BIVAZsBIVA plots based on Z scores (no unit)
IR200/5Impedance ratio (no unit) calculated at the frequencies 200 and 5 kHz
IRfc/5IR calculated at the frequencies fc and 5 kHz.
Groups and impedance parameters studied in this paper

Subjects enrolled

Eight n class="Species">children (al">pan class="Species">boys = 7, girl = 1, 2–10 years of age) with active NS (ANS patient group) were included from the Department of Pediatrics and Adolescent Medicine, Aarhus University Hospital, Denmark. Inclusion criteria were the presence of NS defined by proteinuria > 40 mg/m2/day, plasma albumin < 25 g/L, oedema, and hyperlipidemia. Exclusion criteria were low plasma levels of C3-complement, post-infectious glomerulonephritis, vasculitis such as Henoch-Schönlein nephritis or specific glomerulonephritis, e.g., dense deposit disease. Five of the ANS patients (ANS* subgroup) were also restudied on remission (NSR group). Remission was defined as urinary dipstick negative for protein on three consecutive days. Before treatment with prednisolone and diuretics were initiated, blood samples, blood pressures and impedance measurements were collected in the ANS patient group. To be able to compare collected data, impedance measurements were also available for 38 healthy age-matched control n class="Species">children (HC group) (al">pan class="Species">boys = 23, girls = 15, 2–10 years of age), taken from a previously published dataset [23].

Anthropometry, biochemistry and blood pressure

Prior to the impedance measurements, weight and height were measured, in duplicate, by trained pan class="Species">personnel. Weight was measured on digital scales, with light clothes to within 0.1 kg, and height was measured without shoes, to the nearest 0.5 cm using a stadiometer. For all calculatiopan class="Disease">ns, mean values were applied. Resting venous blood samples and blood pressures (Carescape V100 Monitor, GE Healthcare, USA) were collected in the pan class="Chemical">ANS al">pan class="Species">patient group as part of their routine medical care with analyses undertaken by accredited hospital biomedical scientists.

BIA parameters

Frequencies

Accepted practice is to use n class="Chemical">PA calculated at a frequency of 50 kHz [12, 13]. Similarly, al">pan class="Chemical">BIVA is performed using resistance (R, in Ohm, Ω) and reactance (XC, in Ω) also measured at 50 kHz [13], while the IR in most common use is calculated from measurements of impedance at 5 and 200 kHz [12]. The use of a bioimpedance spectroscopy device, as used in this study, allows determination of the so-called characteristic frequency (fc, kHz), defined as the frequency at which XC reaches its maximum [7]. This frequency (fc) varies from person to person, but can be considered the optimal frequency for measurement of TBW [24]. Consequently, it was decided to explore whether there was advantage in using measurements at fc, in PA, BIVA and IR analyses, as an alternative to the accepted practice described above.

Phase angle (PA)

n class="Chemical">PA (in degrees), was calculated from R and XC (Additional file 1: Figure S1) at both 50 kHz (al">pan class="Chemical">PA50) and fc (PA) by use of the following formula: In this formula, tan−1 trn class="Chemical">ansforms the ratio XC/R into an angle measured in radial">pan class="Chemical">ans, while the factor 180°/π (≈ 57.296) converts radians to degrees (2π in radians is a full circle, i.e., 360°). A larger ratio of XC/R corresponds to a larger PA.

BIVA

The pan class="Chemical">BIVA approach [17, 25] plots the loci of R and XC, standardized by the height (H), i.e., R/H and XC/H (in Ω/m), as a al">pan class="Chemical">bivariate vector in a nomogram. Data for specific populations, notably normative control data, are summarized as tolerance ellipses (see Fig. 1) against which patient data may be compared. Where replicate measurements are available as in the present study, for the NS patients before and after treatment, the different vectors (loci) can be shown in the same plot to visualize any change, such as change in position relative to the tolerance ellipses.
Fig. 1

Interpretation of the BIVA nomogram. Reference values are plotted as so-called tolerance ellipses in the coordinate system with the 50th (∙∙∙∙), 75th (−---) and 95th (──) vector percentile of the healthy reference population. Values outside of the 95th percentile are considered abnormal. The position and length of the vector provides information about disease status and cell membrane function. The length of the vector is related to high or low R values, i.e. dehydration (quadrant 1) and overhydration (quadrant 3), respectively. A migration sideways of the vector due to high or low XC indicates increase (quadrant 2) or decrease (quadrant 4) of dielectric mass (membranes and tissue interfaces) of soft tissues. The same interpretation applies when BIVA plots are prepared based on Z scores. The division into quadrants is meant as an indication only, not as sharp distinctions

Interpretation of the n class="Chemical">BIVA nomogram. Reference values are plotted as so-called tolerance al">pan class="Species">ellipses in the coordinate system with the 50th (∙∙∙∙), 75th (−---) and 95th (──) vector percentile of the healthy reference population. Values outside of the 95th percentile are considered abnormal. The position and length of the vector provides information about disease status and cell membrane function. The length of the vector is related to high or low R values, i.e. dehydration (quadrant 1) and overhydration (quadrant 3), respectively. A migration sideways of the vector due to high or low XC indicates increase (quadrant 2) or decrease (quadrant 4) of dielectric mass (membranes and tissue interfaces) of soft tissues. The same interpretation applies when BIVA plots are prepared based on Z scores. The division into quadrants is meant as an indication only, not as sharp distinctions To better focus on deviation from normative reference values, Z scores were calculated. For a normal material with a mean value (μ) and a standard deviation (σ), the Z score of an observed value X is: In the present paper, Z scores are denoted ZS (no unit) to avoid confusion with the accepted symbol for impedance (Z, in Ω). By definition ZS(μ) = 0, while a deviation by, for example 2 standard deviatiopan class="Disease">ns from the mean value, corresponds to ZS = 2. The n class="Chemical">BIVA plots were tral">pan class="Chemical">ansformed from raw plots to ZS plots by plotting the ZS values instead of the R and XC values. In a BIVA plot transformed to ZS, the tolerance ellipses have center at (0,0), but will still be non-circular because R and XC are not independent variables. In this study, n class="Chemical">BIVA plots were preal">pared from R and XC (raw impedance data), measured at either 50 kHz or fc. These al">pan class="Chemical">BIVA plots will be referred to as BIVARXc, with the corresponding parameters: R50/H and XC50/H, or R/H and XC/H. Correspondingly, BIVA plots transformed to Z scores will be referred to as BIVAZs, with the corresponding parameters: ZS(R50/H) and ZS(XC50/H), or ZS(R/H) and ZS(XC/H).

Impedance ratio (IR)

The theory behind the use of IR’s is that at a sufficiently high frequency electrical current can penetrate the cell membrane, and provide information about the n class="Chemical">TBW, whereas at a low frequency the membrane is essentially impermeable to the electrical current, and only ECW can be measured [26]. While the ideal high and low frequencies are infinite and zero respectively, finite frequencies must be used in practice. The frequency al">pair 200 kHz and 5 kHz is commonly used [5, 12]. Impedance will be lower at 200 kHz than at 5 kHz, and IR200/5 will thus be a number below 1.00. An IR200/5 approaching 1.00 is deemed to indicate fluid overload and poor cellular health [12]. A high ratio is thus an expression that the resistance to electrical current in the body is reduced as a coal">pan class="Disease">nsequence of expansion of the ECW and/or a detriment of the normal function of the cell membrane. The IR (no unit) was calculated from the impedance Z (in Ω) as follows: The ratios copan class="Disease">nsidered were IR200/5 and IR, i.e., both the common choice and investigation of fc as the high frequency.

BIA measurements

pan class="Chemical">BIA measurements were undertaken as far as possible following previously reported standardized testing and reporting procedures [7, 27]. Briefly, the protocol was as follows. n class="Species">Participants were not fasting with no restrictioal">pan class="Disease">ns on voiding but had been requested to refrain from intense physical exercise four hours prior to study. Measurements were performed in an electrically neutral environment with n class="Species">participants lying supine on a non-conductive surface (hospital bed/examination table). al">pan class="Species">Participants were rested in the supine position for 5 min before and during measurement. Participants remained clothed with only hands and feet uncovered with the body positioned with the arms and legs abducted at a 30–45 degree angle from the trunk. Skin surface ECG-style gel electrodes with an area > 4 cm2 (single-Tab. 292-STE, ImpediMed, Brisbane QLD, Australia) were used: voltage (sensor) electrodes were applied at midline (electrode centre-to-centre) between the prominent bone prominences on the dorsal surface of the wrist (ulna and radius), and ankle (medial and lateral malleoli). The current (source) electrodes were placed with the midline 5 cm distal to these positions using a purpose-designed spacer. Where the hands or feet were too small to obtain this separation, the current electrodes were placed as distally as possible on the hand (but not on the fingers or toes), and the voltage electrodes were placed with the midline 5 cm proximal to this position [28]. To secure proper electrode-to-skin adherence and to minimize skin contact impedance, the skin was cleaned with alcohol (ethanol 75%) prior to the placement of electrodes. Whole body (wrist to ankle) impedance was measured using a Xitron 4200, HYDRA pan class="Chemical">BIS device, tested with an electronic verification module (TS4201) weekly according to manufacturer’s ial">pan class="Disease">nstruction, (Xitron Technologies, San Diego, CA, USA). This device measures the electrical parameters R and XC at 50 discrete frequencies in the range from 5 to 1000 kHz. It was en class="Disease">nsured that the device cables were not touching the subject, the subjects’ al">parents, the ground, al">pan class="Chemical">metal objects, routed near high voltage equipment, strong electrical or magnetic fields, and that the cables were not intertwined. All measurements were made by the same trained operator. Furthermore, the measurements were made in triplicate with electrodes remaining in place between measurements, made at room temperature (21o to 25o C) and performed between 08:30 and 15:30. The total measurement time was 7 min, covering patient preparation and impedance measurements. Data were analysed and screened for data quality using the ImpediMed SFB7 Multi-Frequency Analysis software (Bioimp Version 5.4.0.3, Brisbane QLD, Australia) as described previously [29]. Precision of measurement was assessed by the percentage coefficient of variation (CV% = SD/mean ∙ 100%) and deemed acceptable for all groups: CV(R50 and R) ≤ 0.5% and CV(XC50 and XC) ≤ 3.1%.

Statistical data analysis

Results are presented as mean ± standard deviation (SD), after test for normality, using Q-Q plots and the Shapiro-Wilk test. To determine differences in impedance data between n class="Species">patients with active al">pan class="Disease">NS and the same patients at remission (ANS* group vs. NSR group), a paired two-tailed Student’s t-test was used. To compare impedance data between patients with active NS and at remission with controls (ANS group vs. HC group and NSR group vs. HC group), an unpaired two-tailed t-test was used. The statistical software MedCalc® (MedCalc Software, Ostend, Belgium) was used to prepare all statistical tests and graphical illustratiopan class="Disease">ns.

Results

Participant characteristics

Comparison between all the n class="Species">participants enrolled in the study (Additional file 1: Table S1) showed no significant differences in any al">parameters between the al">pan class="Disease">NS and control participants and between the NS sub-groups. All n class="Chemical">ANS al">pan class="Species">patients (Additional file 1: Table S2) had normal or near normal renal function and four of eight patients were hypertensive at admission. Repeat impedance measurements at remission were only possible in five of the n class="Species">patients: two of the al">pan class="Chemical">ANS patients did not recover due to repeated relapses, and one was transferred to another hospital.

Bioimpedance parameters

Impedance data and statistics are presented in Table 2. The main findings are summarized in the following.
Table 2

Measured impedance data and statistics for the included groups

ParameterANSANS*NSRHCANS* vs. NSR(paired)ANS vs. HC(unpaired)NSR vs. HC(unpaired)
Raw impedance data
fc (Hz)144.5 ± 43.1155.8 ± 44.596.8 ± 43.993.2 ± 29.2p < 0.01p < 0.05p > 0.05
 R50 (Ω)421.5 ± 44.7399.3 ± 41.0663.1 ± 61.5721.9 ± 65.3p < 0.001p < 0.001p > 0.05
 Rfc (Ω)403.4 ± 40.9382.1 ± 37.4639.8 ± 58.2694.7 ± 62.7p < 0.001p < 0.001p > 0.05
 XC50 (Ω)22.1 ± 5.418.6 ± 3.463.0 ± 11.966.9 ± 8.1p < 0.01p < 0.001p > 0.05
 XCfc (Ω)24.2 ± 5.721.2 ± 5.272.4 ± 11.273.8 ± 10.1p < 0.001p < 0.001p > 0.05
 Z5 (Ω)442.1 ± 47.9416.2 ± 42.8733.9 ± 65.1794.9 ± 71.6p < 0.001p < 0.001p > 0.05
 Z200 (Ω)396.8 ± 41.2378.0 ± 39.4603.7 ± 59.6656.8 ± 59.9p < 0.001p < 0.001p > 0.05
 Zfc (Ω)404.3 ± 41.1382.8 ± 37.5643.1 ± 58.4698.6 ± 63.0p < 0.001p < 0.001p > 0.05
PA (degrees)
 PA503.0 ± 0.62.7 ± 0.45.5 ± 1.15.3 ± 0.5p < 0.01p < 0.001p > 0.05
 PAfc3.4 ± 0.63.1 ± 0.56.5 ± 1.06.1 ± 0.6p < 0.01p < 0.001p > 0.05
BIVA RXc (Ω/m)
 R50/H356.9 ± 87.6337.2 ± 91.8555.8 ± 166.9579.4 ± 94.9p < 0.01p < 0.001p > 0.05
 Rfc/H341.1 ± 81.0322.4 ± 85.6530.6 ± 142.3556.5 ± 83.4p < 0.01p < 0.001p > 0.05
 XC50/H18.4 ± 4.915.4 ± 3.450.6 ± 7.658.8 ± 9.5p < 0.001p < 0.001p > 0.05
 XCfc/H20.5 ± 6.617.9 ± 6.958.7 ± 10.858.7 ± 10.8p < 0.001p < 0.001p > 0.05
BIVA Zs (no unit)
 ZS(R50/H)−2.3 ± 0.9−2.6 ± 1.0−0.3 ± 1.70.0 ± 1.0p < 0.01p < 0.001p > 0.05
 ZS(Rfc/H)−2.6 ± 1.0−2.8 ± 1.0−0.3 ± 1.70.0 ± 1.0p < 0.01p < 0.001p > 0.05
 ZS(XC50/H)− 4.5 ± 0.6−4.9 ± 0.4−0.4 ± 1.00.0 ± 1.0p < 0.001p < 0.001p > 0.05
 ZS(XCfc/H)−4.0 ± 0.7−4.3 ± 0.70.0 ± 1.10.0 ± 1.0p < 0.001p < 0.001p > 0.05
IR (no unit)
 IR200/50.90 ± 0.020.91 ± 0.010.82 ± 0.030.83 ± 0.02p < 0.01p < 0.0001p > 0.05
 IRfc/50.92 ± 0.010.92 ± 0.010.88 ± 0.010.88 ± 0.01p < 0.001p < 0.001p > 0.05

Data are means ± SD. For group and impedance descriptions, see Table 1. H: height, Z: impedance (Z2 = R2 + XC2), ZS = Z score

For group and impedance descriptions, see Table 1; ZS = Z score; A Student’s t-test was used to determine differences between the groups with statistical significance set at a p-value < 0.05

Measured impedance data and statistics for the included groups Data are mepan class="Chemical">ans ± SD. For group and impedance descriptioal">pan class="Disease">ns, see Table 1. H: height, Z: impedance (Z2 = R2 + XC2), ZS = Z score For group and impedance descriptiopan class="Disease">ns, see Table 1; ZS = Z score; A Student’s t-test was used to determine differences between the groups with statistical significance set at a p-value < 0.05

Phase Angle

The absolute and relative (in brackets) mean differences of the n class="Chemical">PA values for the al">pan class="Chemical">ANS patients compared to the HC were − 2.3 degrees (− 43.4%) for PA50 and − 2.7 degrees (− 44.3%) for PA. For the HC group, PA50 values showed to be comparable with earlier reported reference values (range: 5–7 degrees) for healthy children, adolescents and adults [13, 30], confirming their use as control group in this study. For both n class="Chemical">PA50 and al">pan class="Chemical">PA, significant differences were found between the NS children and the same children at remission (ANS* vs. NSR, both p-values < 0.01) as well as between the NS children and healthy children (ANS vs. HC, both p-values < 0.001). Children in remission had similar results to the healthy children (NSR vs. HC, both p-values > 0.05). The relationship between PA50 in relation to age and weight showed (Additional file 1: Fig. S2) that values for the ANS patients were located outside the confidence intervals of the HC at baseline, but for those participants for whom data at remission was available (i.e. the NSR group), data were now located within or very close to the range of control data. The absolute and relative (in brackets) mean differences of the n class="Chemical">BIVARXc al">parameters for the al">pan class="Chemical">ANS patients compared to the HC were − 222.5 Ω/m (− 38.4%) for R50/H, − 35.0 Ω/m (− 65.5%) for XC50/H, − 215.5 Ω/m (− 38.4%) for R/H and − 38.3 Ω/m (− 65.1%) for XC/H. For the HC group, The absolute mean differences of the pan class="Chemical">BIVAZs al">parameters for the al">pan class="Chemical">ANS patients compared to the HC were − 2.3 for ZS(R50/H), − 4.5 for ZS(XC50/H), − 2.6 for ZS(R/H) and − 4.0 for ZS(XC/H). For both n class="Chemical">BIVARXc and al">pan class="Chemical">BIVAZs, significant differences were found between the NS children and the same children at remission (ANS* vs. NSR, all p-values < 0.01) as well as between the NS children and healthy children (ANS vs. HC, all p-values < 0.001). Children in remission had similar results to the healthy children (NSR vs. HC, all p-values > 0.05). Figure 2 shows the n class="Chemical">BIVA graphs measured at 50 kHz for all the groups (al">pan class="Chemical">ANS/ANS* and NSR as points, HC as reference ellipses). Graphs measured at the characteristic frequency fc were very similar and are not shown. From the graphs it appears that the ANS patients were found outside the reference ellipse and in the quadrant that represents overhydration. At remission, vectors had moved along a trajectory that had returned the ANS participants to within the reference ellipse except for one ANS patient that was now located in the quadrant indicative of dehydration.
Fig. 2

BIVA plots. BIVARXc and BIVAZs graphs calculated on the basis of 50 kHz. Reference ranges of the HC are indicated as 50th (∙∙∙∙), 75th (−---) and 95th (──) tolerance ellipses. ∆: ANS, ▲: NSR. To identify impedance changes, the plots are connected with dotted lines for the five ANS patients measured in the period of remission. For group and impedance descriptions, see Table 1

n class="Chemical">BIVA plots. al">pan class="Chemical">BIVARXc and BIVAZs graphs calculated on the basis of 50 kHz. Reference ranges of the HC are indicated as 50th (∙∙∙∙), 75th (−---) and 95th (──) tolerance ellipses. ∆: ANS, ▲: NSR. To identify impedance changes, the plots are connected with dotted lines for the five ANS patients measured in the period of remission. For group and impedance descriptions, see Table 1

Impedance ratios

The absolute and relative (in brackets) mean differences for the pan class="Chemical">ANS al">pan class="Species">patients compared to the HC were 0.07 (8.4%) for IR200/5 and 0.04 (4.5%) for IR. For both ratios studied, n class="Disease">NS al">pan class="Species">children were significantly different from the same children at remission (ANS* vs. NSR, both p-values < 0.01), and NS children were different from healthy children (ANS vs. HC, both p-values < 0.01), while no significant differences were found between children in remission and healthy children (NSR vs. HC, both p-values > 0.05). The relation class="Disease">nship between the IR200/5 and age and weight for all three groups are presented in Fig. 3. The ratios for the al">pan class="Chemical">ANS patients were located outside the confidence intervals of the HC at baseline, but moved to be located within or very close to the normal range at remission. One ANS patient was notable for being an apparent outlier for weight (Fig. 3); this patient’s weight was at the 100th percentile from the ‘WHO child growth standards’ [31]).
Fig. 3

Relationship between impedance ratios and participants’ age and weight. ∆: ANS, ▲: NSR, ○: HC; For group and impedance descriptions, see Table 1; Regression lines are based on the HC data. Dashed lines are 95% confidence intervals for regression lines

Relation class="Disease">nship between impedance ratios and al">pan class="Species">participants’ age and weight. ∆: ANS, ▲: NSR, ○: HC; For group and impedance descriptions, see Table 1; Regression lines are based on the HC data. Dashed lines are 95% confidence intervals for regression lines

Discussion

This study has demon class="Disease">nstrated that al">pan class="Chemical">BIA is capable of distinguishing NS patients from healthy controls and is capable of tracking recovery of patients at remission. In contrast to earlier BIA studies in children with NS, where prediction equations have been used [32, 33], the current study, and a recently published bioimpedance study in the same group of children [34], used raw BIA data free of the assumptions that underlie prediction equations for body water volumes. These assumptions, for example, constant hydration, are questionable in many clinical situations, and provide results open to misinterpretation [12, 35]. Three approaches to the use of raw impedance data were con class="Disease">nsidered: al">pan class="Chemical">PA, impedance ratios and BIVA plots. It is appropriate to consider the relative advantages and disadvantages of each. Low n class="Chemical">PA values have been previously associated with ill health. al">pan class="Chemical">PA values below 3.0 degrees were found to be an independent predictor of poor survival in haemodialysis patients [36]. This value showed to be in agreement with the mean value of 3.0 degrees observed in the ANS patients. Similarly, low PA values (male: 4.21 degrees; female: 4.38 degrees) have been observed in children suffering from sickle cell disease (SCD) [37] and malnutrition (2.4 degrees) [38]. In contrast to n class="Chemical">PA, al">pan class="Chemical">BIVA plots make it possible to differentiate between two identical PA values that may represent two different physiological conditions (cf. Figure 1) as well as the relation between XC and R which is subsumed into the single PA value. A disadvantage of BIVA plots is, however, the time required to prepare such plots for pediatric patients. Although some commercially available BIA devices provide BIVA plots in their software, unfortunately they do not include reference ranges for pediatric populations. Compared to pan class="Chemical">PA and al">pan class="Chemical">BIVA (both calculated at 50 kHz), impedance ratios provide information related to body water distribution, i.e. ECW relative to TBW. In previous studies, IR has proven to be a more sensitive indicator of malnutrition than PA [39]. To be clinically useful, interpretation of IRs requires normative data (cut-points) obtained in comparable populations; unfortunately, at present, no normative data are available for the pediatric population. In healthy adults, mean IR200/5 cut-points of between ≤0.78 and ≤ 0.82, respectively, have been reported as limits for normal IR200/5 [39], and reference cut-points based on ethnicity for healthy adults have been prepared by NHANES [30]. For comparison, the mean IR200/5 was 0.83 in our pediatric HC group, i.e. slightly above the adult cut-point. Studies in adults have demon class="Disease">nstrated that ratios progressively closer to 1.00 are linked to fluid overload, poor cellular health and poor clinical outcomes [12]; by comal">parison a mean ratio of 0.90 was observed in the al">pan class="Chemical">ANS patients. The rationale for calculating IR at frequencies 5 and 200 kHz, is that 5 kHz is sufficiently low to provide an accurate measure of ECW while 200 kHz is sufficiently high that a large proportion of the electrical current penetrates the cell membrane and thus will provide a more accurate measure of TBW [12, 40]. The secondary aim of the present study was to explore whether there was advantage in using n class="Chemical">PA, al">pan class="Chemical">BIVA and IR measurements obtained at fc, as alternative to the widely used 50 kHz. Even though fc has been suggested as the optimal frequency for impedance measurements in humans [5], our data, however, do not support this contention, since the patient and control groups were equally well separated by measurements at either frequency. This observation is consistent with the finding that measurements of impedance at fc are no better predictors of body composition than at 50 kHz [40]. It should be emphasized that using a wrist to ankle measurement protocol, as used in this study, fc is the average value of the individual fc values for all tissues within the conductive route. All tissues display different and unique fc’s that depend upon their physical structure. Whole body impedance measurements are predominantly determined by the impedance of skeletal muscle tissue [41]. Thus it is possible that the increased fc observed in the ANS patients is indicative of changes in skeletal muscle; a hypothesis consistent with NS being a systemic condition. Limitation class="Disease">ns of the present study were the low number of al">pan class="Species">patients enrolled, which is a consequence of the low incidence of the disease with only around 2 new cases per 100,000 [42]. Despite the risk that the small number of patients is not representative of NS patients in general, we do not consider this to be a serious problem as they exhibited the same clinical characteristics as previous patients in the clinic. pan class="Chemical">BIVA plots for the reference population are normally adjusted for age, BMI and gender. This was not possible in this study due to the limited number of controls enrolled. An adjusted n class="Chemical">BIVA plot is likely to exhibit narrower normal ranges, i.e. smaller tolerance al">pan class="Species">ellipses. Figure 2 demonstrates that the BIVA data of the ANS children were clearly outside the normal tolerance ellipses, tighter normal ranges would amplify these differences. Generally, no attempt was made to adjust for sex differences, again due to small sample size, even though significant differences between the sexes regarding relative fat mass and lean body mass (LBM) even when adjusted by height have been found in studies in healthy pan class="Species">children [43].

Conclusion

This study demopan class="Disease">nstrated that al">pan class="Chemical">PA, BIVA and IR may be clinically useful to monitor changes in disease status in pediatric NS patients. NS is characterized by leakage of large amounts of proteins from the kidneys into the urine, with consequent hypoalbuminemia and oedema formation. Sodium retention is the major clinical feature of NS and the primary cause of the oedema formation. PA and BIVA measurements can be obtained using simple inexpensive single frequency bioimpedance devices. Multi-frequency devices are required if IR is applied for additional information on the relative sizes of body water compartments, i.e. ECW and TBW. In order to increase the clinical utility of the approaches considered here, standardized population-specific reference data from childhood to puberty are required. The present results are promising, in that they demon class="Disease">nstrate the potential of al">pan class="Chemical">BIA as an alternative clinical tool to repeated daily weighing as a measure of fluid overload. Weight change is a poor prognostic indicator since premorbid weight is often influenced by recall bias from the carers of the child and the weight of a child will change over time, especially in NS patients treated with prednisolone which enhances appetite markedly. Finally, although the present data do not provide a physiological mechanism for changes in disease status in pan class="Disease">NS, changes in tissue reactance imply changes in cell membrane function with coal">pan class="Disease">nsequent impacts upon tissue water distribution. Further studies are required to confirm this suggestion. Figure S1. Raw impedance data in the impedance plane. Figure S2. Relation class="Disease">nship between phase angle and al">pan class="Species">participants’ age and weight. Table S1. Characteristics of the study subjects. Table S2. Clinical data for the ANS patients. (PDF 201 kb)
  35 in total

1.  Phase angle and n-3 polyunsaturated fatty acids in sickle cell disease.

Authors:  D J VanderJagt; Y-S Huang; L-T Chuang; C Bonnett; R H Glew
Journal:  Arch Dis Child       Date:  2002-09       Impact factor: 3.791

2.  Importance of electrode position in bioelectrical impedance analysis.

Authors:  A Gartner; B Maire; F Delpeuch; P Sarda; R P Dupuy; D Rieu
Journal:  Am J Clin Nutr       Date:  1992-12       Impact factor: 7.045

Review 3.  Bioelectrical impedance analysis--part I: review of principles and methods.

Authors:  Ursula G Kyle; Ingvar Bosaeus; Antonio D De Lorenzo; Paul Deurenberg; Marinos Elia; José Manuel Gómez; Berit Lilienthal Heitmann; Luisa Kent-Smith; Jean-Claude Melchior; Matthias Pirlich; Hermann Scharfetter; Annemie M W J Schols; Claude Pichard
Journal:  Clin Nutr       Date:  2004-10       Impact factor: 7.324

4.  Bioelectrical impedance analysis at the characteristic frequency.

Authors:  Leigh C Ward; Bruce H Cornish
Journal:  Nutrition       Date:  2006-10-25       Impact factor: 4.008

5.  Phase angle from bioelectrical impedance analysis: population reference values by age, sex, and body mass index.

Authors:  Anja Bosy-Westphal; Sandra Danielzik; Ralf-Peter Dörhöfer; Wiebke Later; Sonja Wiese; Manfred J Müller
Journal:  JPEN J Parenter Enteral Nutr       Date:  2006 Jul-Aug       Impact factor: 4.016

6.  Measurement of body water by multifrequency bioelectrical impedance spectroscopy in a multiethnic pediatric population.

Authors:  K J Ellis; R J Shypailo; W W Wong
Journal:  Am J Clin Nutr       Date:  1999-11       Impact factor: 7.045

7.  The validity of bioelectrical impedance phase angle for nutritional assessment in children.

Authors:  M Nagano; S Suita; T Yamanouchi
Journal:  J Pediatr Surg       Date:  2000-07       Impact factor: 2.545

8.  Phase angle from bioelectrical impedance analysis remains an independent predictive marker in HIV-infected patients in the era of highly active antiretroviral treatment.

Authors:  A Schwenk; A Beisenherz; K Römer; G Kremer; B Salzberger; M Elia
Journal:  Am J Clin Nutr       Date:  2000-08       Impact factor: 7.045

9.  Norms and correlates of bioimpedance phase angle in healthy human subjects, hospitalized patients, and patients with liver cirrhosis.

Authors:  Oliver Selberg; Daniela Selberg
Journal:  Eur J Appl Physiol       Date:  2002-01-31       Impact factor: 3.078

Review 10.  Nephrotic syndrome in childhood.

Authors:  Allison A Eddy; Jordan M Symons
Journal:  Lancet       Date:  2003-08-23       Impact factor: 79.321

View more
  3 in total

Review 1.  Using bioelectrical impedance analysis in children and adolescents: Pressing issues.

Authors:  Camila E Orsso; Maria Cristina Gonzalez; Michael Johannes Maisch; Andrea M Haqq; Carla M Prado
Journal:  Eur J Clin Nutr       Date:  2021-10-07       Impact factor: 4.884

2.  SOFA Score Plus Impedance Ratio Predicts Mortality in Critically Ill Patients Admitted to the Emergency Department: Retrospective Observational Study.

Authors:  Ashuin Kammar-García; Lilia Castillo-Martínez; Javier Mancilla-Galindo; José Luis Villanueva-Juárez; Anayeli Pérez-Pérez; Héctor Isaac Rocha-González; Jesús Arrieta-Valencia; Miguel Remolina-Schlig; Thierry Hernández-Gilsoul
Journal:  Healthcare (Basel)       Date:  2022-04-27

3.  Mitochondrial DNA methylation and copy number predict body composition in a young female population.

Authors:  Laura Bordoni; Vanessa Smerilli; Cinzia Nasuti; Rosita Gabbianelli
Journal:  J Transl Med       Date:  2019-11-28       Impact factor: 5.531