Literature DB >> 31435454

Flexible, Structured MWCNT/PDMS Sensor for Chronic Vascular Access Monitoring.

Steve J A Majerus1, Jeremy Dunning1, Joseph A Potkay1,2, Kath M Bogie1,3.   

Abstract

Graft wall pulsation amplitude sensing can provide a measure of functional status, e.g. in hemodialysis access grafts. Current implantable graft monitoring sensors require graft modification and direct bloodstream contact. We propose a new class of piezoresistive flexible pulsation sensors which can be wrapped around the graft to measure wall movement. These sensors must be highly flexible to prevent graft constriction; typical strain sensors are too rigid and the strain sensing range is too limited for this application. We describe a novel additive manufacturing (AM) method for printing polydimethylsiloxane (PDMS) with an internal porous structure, such that material compliance may be tuned anisotropically for a given sensor geometry. Prototype flexible pulsation sensors (FPS) consisting of structured PDMS with an embedded conductive PDMS sensor layer were fabricated and tested. Initial tests demonstrated reliable sensor response to 1-Hz cyclic elongation of 20%, and a sensor gauge factor of 1.0.

Entities:  

Year:  2017        PMID: 31435454      PMCID: PMC6703556          DOI: 10.1109/ICSENS.2016.7808630

Source DB:  PubMed          Journal:  Proc IEEE Sens        ISSN: 1930-0395


  6 in total

Review 1.  Improving vascular grafts: the importance of mechanical and haemodynamic properties.

Authors:  S E Greenwald; C L Berry
Journal:  J Pathol       Date:  2000-02       Impact factor: 7.996

2.  An inductively powered implantable blood flow sensor microsystem for vascular grafts.

Authors:  Jia Hao Cheong; Simon Sheung Yan Ng; Xin Liu; Rui-Feng Xue; Huey Jen Lim; Pradeep Basappa Khannur; Kok Lim Chan; Andreas Astuti Lee; Kai Kang; Li Shiah Lim; Cairan He; Pushpapraj Singh; Woo-Tae Park; Minkyu Je
Journal:  IEEE Trans Biomed Eng       Date:  2012-06-06       Impact factor: 4.538

3.  Cell electrospinning: a unique biotechnique for encapsulating living organisms for generating active biological microthreads/scaffolds.

Authors:  Andrea Townsend-Nicholson; Suwan N Jayasinghe
Journal:  Biomacromolecules       Date:  2006-12       Impact factor: 6.988

4.  Necessity for elastic properties in synthetic arterial grafts.

Authors:  E R Gozna; W F Mason; A E Marble; D A Winter; F G Dolan
Journal:  Can J Surg       Date:  1974-05       Impact factor: 2.089

5.  Evaluation and performance standards for arterial prostheses.

Authors:  W M Abbott; A Callow; W Moore; R Rutherford; F Veith; S Weinberg
Journal:  J Vasc Surg       Date:  1993-04       Impact factor: 4.268

6.  Print your own membrane: direct rapid prototyping of polydimethylsiloxane.

Authors:  Tim Femmer; Alexander J C Kuehne; Matthias Wessling
Journal:  Lab Chip       Date:  2014-05-15       Impact factor: 6.799

  6 in total
  2 in total

1.  Vascular Pressure-Flow Measurement Using CB-PDMS Flexible Strain Sensor.

Authors:  Hao Chong; Jiongcheng Lou; Kath M Bogie; Christian A Zorman; Steve J A Majerus
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-10-10       Impact factor: 3.833

Review 2.  Piezoelectric Signals in Vascularized Bone Regeneration.

Authors:  Delfo D'Alessandro; Claudio Ricci; Mario Milazzo; Giovanna Strangis; Francesca Forli; Gabriele Buda; Mario Petrini; Stefano Berrettini; Mohammed Jasim Uddin; Serena Danti; Paolo Parchi
Journal:  Biomolecules       Date:  2021-11-20
  2 in total