Use of a surface magnet in the extraction of another magnet aspirated into the bronchus of a 7-year-old girl.

Sumeet Narang1, Jayateertha Joshi1, Sunil Baikadi Vasudevarao2, Suchetha Rao3.   

Abstract

A 7-year-old girl presented to the emergency room (ER) with alleged history of aspiration of a toy magnet. The challenge was to safely extract the foreign body. A bronchoscopic approach with forceps, or Dormia basket, or Fogarty catheter, was considered, but these approaches had disadvantages, such as slipping or impaction of the object, and oxygen desaturation. Applying principles of removal of intraocular metallic objects in ophthalmologic surgery using magnetism, the object was removed with the help of another larger surface magnet. The location of the foreign body was confirmed by bronchoscopy. A Fogarty catheter was introduced distal to the object, under bronchoscopic guidance. A strong surface magnet was then placed on the surface of the chest and under C-arm guidance, the object was moved from the bronchus to the trachea. Once at the vocal cords, the Fogarty catheter was inflated to prevent it from slipping back and the magnet was extracted using forceps. © BMJ Publishing Group Limited 2019. No commercial re-use. See rights and permissions. Published by BMJ.

Entities:  

Keywords:  emergency medicine; head and neck surgery; paediatric surgery

Mesh:

Year:  2019        PMID: 31434671      PMCID: PMC6706659          DOI: 10.1136/bcr-2019-230107

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  1 in total

1.  The usage of a magnet-powered instrument in the extraction of metallic or magnetic aspirated foreign bodies: A case report.

Authors:  Mehdi Sarafi; Mohsen Rouzrokh; Saeed Sadr; Seyed Alireza Mahdavi; Nastaran Sadat Mahdavi; Manoochehr Ebrahimian
Journal:  Int J Surg Case Rep       Date:  2022-09-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.