Mass spectrometry-based intraoperative tumor diagnostics: a letter in reply.

Isabelle Fournier1, Michel Salzet1.   

Abstract

Entities:  

Keywords:  SpiderMass; cancer; guided surgery; intraoperative tumor diagnostics; real-time diagnosis; surgery; tumor margin

Year:  2019        PMID: 31428449      PMCID: PMC6695522          DOI: 10.2144/fsoa-2019-0037

Source DB:  PubMed          Journal:  Future Sci OA        ISSN: 2056-5623


× No keyword cloud information.
We wish to offer our perspective and expertise concerning the review article entitled ‘mass spectrometry-based intra-operative tumor diagnosis’ written by Lorena Hänel et al. in Future Science OA. We were struck reading this article by the fact that the authors did not properly address the state-of-the-art of the field in their review and were not addressing all the technologies developed over the past years to address intraoperative tumor diagnostic by MS. As a matter of fact, the authors fail to mention the SpiderMass technology. Therefore, they provide inadequate and not up-to-date citation on this discussed topic. In 2014, PRISM lab (Lille, France) introduced the water-assisted laser desorption/ionization MS (SpiderMass) and filed the patent (PCT/IB2015/057301) [1]. Similar to iKnife [2] and MassSpec Pen [3], the SpiderMass constitutes a micro-sampling probe, transfer line and MS analyzer. The system is based on laser ablation in the infrared (IR) wavelength tuned to excite the most intense vibrational band (O–H) of water molecules, called water-assisted laser ionisation/desorption process. The water constitutes an average 70–80% of the tissues in the human body, and can act as an endogenous matrix and provide analyte ionization as in conventional MALDI [4]. After the laser ablation, ions are collected using the MS vacuum via polymeric tubing positioned just above the analyzed tissue and connected directly to the inlet of the MS source. In this way, the aerosol is delivered to the analyzer, without the need of post-ionization device. As a result, the molecular profiles of ablated tissue are acquired, and can be further compared with a databank containing recorded ex vivo molecular profiles of a cohort of biopsies for example. One of the major advantages of the SpiderMass system is its low invasiveness and painless sampling, tissues being reversibly dehydrated. Another advantage and specific characteristic of SpiderMass is the very low fragmentation observed in the spectra and the possible operation in both positive and negative ion modes with good sensitivity. The system was successfully applied for cancer biopsies analysis ex vivo and then was shown for allowing real-time analysis of human skin in vivo as presented for the first time in 2015 at the ASMS conference and then published in 2016 [5]. The publication evidently shows the first use of a laser-based system coupled to a mass spectrometer for in vivo analysis and its potential to be used in intraoperative diagnostics. Over the past few years, the system was used to analyze genetically modified macrophage cell lines [6] as well as intact proteins. The latest publication in 2018 showed the analysis of dog sarcoma samples ex vivo, allowing for correct classification (97% of specificity) of tumor type and grading [7]. Furthermore, the system demonstrated its applicability for in vivo intraoperative analysis at the surgery room in a veterinary clinic on dog patients [7]. A recent publication in Cancer Cell by Dr Emily Z Keung and Christina L Roland, from the Department of Surgery Oncology of The University of Texas MD Anderson Cancer Center, acknowledged this work and mentioned the SpiderMass system as a step forward in the right direction for molecular cancer diagnostics [8]. The aforementioned examples clearly show that the PRISM Laboratory with its SpiderMass technology is one of the important research groups developing MS-based intraoperative diagnostics [9].
  8 in total

1.  Remote Atmospheric Pressure Infrared Matrix-Assisted Laser Desorption-Ionization Mass Spectrometry (Remote IR-MALDI MS) of Proteins.

Authors:  Benoit Fatou; Michael Ziskind; Philippe Saudemont; Jusal Quanico; Cristian Focsa; Michel Salzet; Isabelle Fournier
Journal:  Mol Cell Proteomics       Date:  2018-04-13       Impact factor: 5.911

2.  In vivo, in situ tissue analysis using rapid evaporative ionization mass spectrometry.

Authors:  Karl-Christian Schäfer; Júlia Dénes; Katalin Albrecht; Tamás Szaniszló; Júlia Balog; Réka Skoumal; Mária Katona; Miklós Tóth; Lajos Balogh; Zoltán Takáts
Journal:  Angew Chem Int Ed Engl       Date:  2009       Impact factor: 15.336

3.  Real time and in vivo pharmaceutical and environmental studies with SpiderMass instrument.

Authors:  B Fatou; P Saudemont; M Duhamel; M Ziskind; C Focsa; M Salzet; I Fournier
Journal:  J Biotechnol       Date:  2018-06-20       Impact factor: 3.307

4.  Accurate and Reproducible Diagnosis of Canine Soft Tissue Sarcoma Using Mass Spectrometry: A Step in the Right Direction.

Authors:  Emily Z Keung; Christina L Roland
Journal:  Cancer Cell       Date:  2018-11-12       Impact factor: 31.743

5.  Nondestructive tissue analysis for ex vivo and in vivo cancer diagnosis using a handheld mass spectrometry system.

Authors:  Jialing Zhang; John Rector; John Q Lin; Jonathan H Young; Marta Sans; Nitesh Katta; Noah Giese; Wendong Yu; Chandandeep Nagi; James Suliburk; Jinsong Liu; Alena Bensussan; Rachel J DeHoog; Kyana Y Garza; Benjamin Ludolph; Anna G Sorace; Anum Syed; Aydin Zahedivash; Thomas E Milner; Livia S Eberlin
Journal:  Sci Transl Med       Date:  2017-09-06       Impact factor: 17.956

6.  Real-Time Molecular Diagnosis of Tumors Using Water-Assisted Laser Desorption/Ionization Mass Spectrometry Technology.

Authors:  Philippe Saudemont; Jusal Quanico; Yves-Marie Robin; Anna Baud; Julia Balog; Benoit Fatou; Dominique Tierny; Quentin Pascal; Kevin Minier; Mélissa Pottier; Cristian Focsa; Michael Ziskind; Zoltan Takats; Michel Salzet; Isabelle Fournier
Journal:  Cancer Cell       Date:  2018-10-18       Impact factor: 31.743

Review 7.  Mass spectrometry-based intraoperative tumor diagnostics.

Authors:  Lorena Hänel; Marcel Kwiatkowski; Laura Heikaus; Hartmut Schlüter
Journal:  Future Sci OA       Date:  2019-03-07

8.  In vivo Real-Time Mass Spectrometry for Guided Surgery Application.

Authors:  Benoit Fatou; Philippe Saudemont; Eric Leblanc; Denis Vinatier; Violette Mesdag; Maxence Wisztorski; Cristian Focsa; Michel Salzet; Michael Ziskind; Isabelle Fournier
Journal:  Sci Rep       Date:  2016-05-18       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.