Ablation using 3D maps adjusted for spatial displacement of premature ventricular complexes relative to sinus beats: Improving precision by correcting for the shift.

Curtis M Steyers1, Sandeep Sodhi1, Mitchell N Faddis1, Daniel H Cooper1, Phillip S Cuculich1, Amit Noheria1.   

Abstract

INTRODUCTION: Point-by-point 3-dimensional (3D) electroanatomic mapping (EAM) is used to guide catheter ablation of premature ventricular complexes (PVCs). Due to the differences in the spatial excursion of the cardiac chambers during cardiac cycles in PVCs vs sinus rhythm, the 3D location registration during PVCs is shifted relative to sinus rhythm. In this study, we describe our strategy to adjust for this displacement in real-time during PVC mapping. METHODS AND
RESULTS: We report 21 patients who underwent catheter ablation of 23 unique PVCs using Carto 3. After mapping the earliest site for each PVC, we reregistered its 3D location to a sinus rhythm beat in real-time, and used this to guide ablation lesion delivery. The PVC earliest location was spatially displaced from the successful ablation lesion in sinus rhythm by average 6.7 (range 3.3-13.0) mm. Offline, we subsequently analyzed 25 unique chamber maps and 606 PVC points. For each point, we reregistered the 3D location to a preceding sinus beat. The PVC points were displaced from sinus rhythm location by average 4.4 (0.3-13.7) mm. The maximally displaced point for each chamber was 7.7 (4.7-13.7) mm. The general direction of shift during PVC was leftward and inferior relative to sinus rhythm.
CONCLUSIONS: During electroanatomic mapping of PVCs using the Carto 3 system, points mapped during PVCs are spatially displaced relative to their location in sinus rhythm. Electrophysiologists should recognize this phenomenon and account for the shift to guide accurate delivery of ablation lesions.
© 2019 Wiley Periodicals, Inc.

Entities:  

Keywords:  catheter ablation; electroanatomic mapping; premature ventricular complexes

Mesh:

Year:  2019        PMID: 31424125     DOI: 10.1111/jce.14120

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  2 in total

1.  Spatial correction improves accuracy of catheter positioning during ablation of premature ventricular contractions: differences between ventricular outflow tracts and other localizations.

Authors:  M Nies; R Schleberger; L Dinshaw; N Klatt; P Muenkler; C Jungen; L Rottner; M D Lemoine; B Reißmann; A Rillig; A Metzner; P Kirchhof; C Meyer
Journal:  BMC Cardiovasc Disord       Date:  2022-07-13       Impact factor: 2.174

2.  Rotational Activation Pattern During Functional Substrate Mapping: Novel Target for Catheter Ablation of Scar-Related Ventricular Tachycardia.

Authors:  Masayuki Hattori; Yuki Komatsu; Qasim J Naeemah; Yuichi Hanaki; Noboru Ichihara; Chihiro Ota; Takeshi Machino; Kenji Kuroki; Hiro Yamasaki; Miyako Igarashi; Kazutaka Aonuma; Akihiko Nogami; Masaki Ieda
Journal:  Circ Arrhythm Electrophysiol       Date:  2021-12-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.