Literature DB >> 31421809

Development of a finite element musculoskeletal model with the ability to predict contractions of three-dimensional muscles.

Junyan Li1, Yongtao Lu2, Stuart C Miller3, Zhongmin Jin4, Xijin Hua5.   

Abstract

Representation of realistic muscle geometries is needed for systematic biomechanical simulation of musculoskeletal systems. Most of the previous musculoskeletal models are based on multibody dynamics simulation with muscles simplified as one-dimensional (1D) line-segments without accounting for the large muscle attachment areas, spatial fibre alignment within muscles and contact and wrapping between muscles and surrounding tissues. In previous musculoskeletal models with three-dimensional (3D) muscles, contractions of muscles were among the inputs rather than calculated, which hampers the predictive capability of these models. To address these issues, a finite element musculoskeletal model with the ability to predict contractions of 3D muscles was developed. Muscles with realistic 3D geometry, spatial muscle fibre alignment and muscle-muscle and muscle-bone interactions were accounted for. Active contractile stresses of the 3D muscles were determined through an efficient optimization approach based on the measured kinematics of the lower extremity and ground force during gait. This model also provided stresses and strains of muscles and contact mechanics of the muscle-muscle and muscle-bone interactions. The total contact force of the knee predicted by the model corresponded well to the in vivo measurement. Contact and wrapping between muscles and surrounding tissues were evident, demonstrating the need to consider 3D contact models of muscles. This modelling framework serves as the methodological basis for developing musculoskeletal modelling systems in finite element method incorporating 3D deformable contact models of muscles, joints, ligaments and bones.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D finite element muscle model; Gait; Knee biomechanics; Musculoskeletal model; Optimization of muscle contraction

Mesh:

Year:  2019        PMID: 31421809     DOI: 10.1016/j.jbiomech.2019.07.042

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  4 in total

1.  Comparison of Biomechanical Performance of Five Different Treatment Approaches for Fixing Posterior Pelvic Ring Injury.

Authors:  Yongtao Lu; Yiqian He; Weiteng Li; Zhuoyue Yang; Ruifei Peng; Li Yu
Journal:  J Healthc Eng       Date:  2020-01-22       Impact factor: 2.682

Review 2.  A Critical Review of the Design, Manufacture, and Evaluation of Bone Joint Replacements for Bone Repair.

Authors:  Yi Huo; Yongtao Lyu; Sergei Bosiakov; Feng Han
Journal:  Materials (Basel)       Date:  2021-12-26       Impact factor: 3.623

3.  S2-alar-iliac screw and S1 pedicle screw fixation for the treatment of non-osteoporotic sacral fractures: a finite element study.

Authors:  Jianxiong Zheng; Xiaoreng Feng; Jie Xiang; Fei Liu; Frankie K L Leung; Bin Chen
Journal:  J Orthop Surg Res       Date:  2021-10-30       Impact factor: 2.359

4.  Three dimensional analysis of hip joint reaction force using Q Hip Force (AQHF) software: Implication as a diagnostic tool.

Authors:  Amany Eid Abd El-Tawab; Aisha Farhana
Journal:  PLoS One       Date:  2022-09-26       Impact factor: 3.752

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.