BACKGROUND: Absence of interlobar collateral ventilation is key to successful endobronchial valve treatment in patients with severe emphysema and can be functionally assessed by using the Chartis measurement. This system has been validated during spontaneous breathing, undergoing procedural sedation (PS), but can also be performed under general anesthesia. Performing the Chartis measurement under PS is often challenging because of coughing, mucus secretion, and difficulties in maintaining an adequate level of sedation. The objective of this study was to investigate whether there is a difference in Chartis measurement outcomes between PS and general anesthesia.
METHODS: In this prospective study, patients underwent Chartis measurements under both PS and general anesthesia. Study outcomes were Chartis measurement duration, number of measurements, feasibility, and success rate.
RESULTS: The study included 30 patients with severe emphysema (mean age, 62 years; median FEV1, 29% of predicted). Chartis measurement duration was significantly longer under PS than under general anesthesia (mean, 20.3 ± 4.2 min vs 15.1 ± 4.4 min; P < .001). There was no difference in the number (median [range]) of measurements performed (2 [1-3] for PS vs 1 [1-3] for general anesthesia; P = 1.00). Chartis measurement was more feasible during general anesthesia (median sum of all feasibility scores, 12 [range, 6-26] for PS vs 7 [5-13] for general anesthesia; P < .001). There was no statistical difference in success rate: 77% of PS cases vs 97% of general anesthesia cases (P = .07).
CONCLUSIONS: This study found that Chartis measurement under general anesthesia is faster and more feasible to perform compared with performance with PS, without affecting measurement outcomes. TRIAL REGISTRATION: Clinicaltrials.gov; No. NCT03205826; URL: www.clinicaltrials.gov.
Copyright © 2019 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Chartis measurement; collateral ventilation; endobronchial valve treatment; general anesthesia; procedural sedation

Mesh:

Year:  2019        PMID: 31421111     DOI: 10.1016/j.chest.2019.07.025

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  2 in total

Review 1.  Endobronchial Valves for the Treatment of Advanced Emphysema.

Authors:  Karin Klooster; Dirk-Jan Slebos
Journal:  Chest       Date:  2020-12-17       Impact factor: 9.410

2.  An adjusted and time-saving method to measure collateral ventilation with Chartis.

Authors:  T David Koster; Karin Klooster; Hallie McNamara; Narinder S Shargill; Sri Radhakrishnan; Ryan Olivera; Dirk-Jan Slebos
Journal:  ERJ Open Res       Date:  2021-07-26
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.