Error evaluation of the D-shuttle dosimeter technique in positron emission tomography study.

Md Shahidul Islam1,2,3, Shoichi Watanuki4, Manabu Tashiro4, Hiroshi Watabe5,6.   

Abstract

The D-shuttle dosimeter technique is a convenient approach for estimating the radiation dosimetry in a positron emission tomography (PET) study that employs multiple D-shuttle dosimeters attached to the body surface of a patient. To bring this technique into clinical usage, it is very important to evaluate its performance by investigating the bias associated with D-shuttle dosimeter positioning and by comparing the estimates with those of the whole-body dynamic PET imaging technique. The torso cavity and six spheres of the NEMA body phantom were filled with 18F-FDG solution, and then, the phantom was imaged for 1 h. We assumed the mislocated positioning of the D-shuttle dosimeters by shifting them in the z-direction (upper) in a range of 1-5 cm from the original positions. The cumulative radioactivities, absorbed doses, and effective dose were estimated using accurate and mislocated positions of the D-shuttle dosimeters. For comparison, the cumulative radioactivities were also estimated from the PET images, and then, the absorbed doses and effective dose were computed. The maximum bias of the average estimated cumulated radioactivities and the effective doses was - 15.0% and - 19.7% for the 1 cm shifted positions, respectively. The ratios of absorbed doses obtained from D-shuttle and PET measurement against the actual values were between 0.9 and 1.3, and 0.7 and 1.0, respectively. The bias associated with the D-shuttle dosimeter positions was significant and probably consistent, and both dosimetric techniques exhibited good performance in this phantom study.

Entities:  

Keywords:  D-shuttle dosimeter positioning; D-shuttle dosimeter technique; Error; Whole-body dynamic PET imaging

Mesh:

Year:  2019        PMID: 31420776     DOI: 10.1007/s12194-019-00530-w

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  12 in total

1.  AMIDE: a free software tool for multimodality medical image analysis.

Authors:  Andreas Markus Loening; Sanjiv Sam Gambhir
Journal:  Mol Imaging       Date:  2003-07       Impact factor: 4.488

Review 2.  How does it work? Positron emission tomography.

Authors:  Abi Berger
Journal:  BMJ       Date:  2003-06-28

3.  MIRD pamphlet No. 21: a generalized schema for radiopharmaceutical dosimetry--standardization of nomenclature.

Authors:  Wesley E Bolch; Keith F Eckerman; George Sgouros; Stephen R Thomas
Journal:  J Nucl Med       Date:  2009-03       Impact factor: 10.057

4.  Internal radiation dose estimation using multiple D-shuttle dosimeters for positron emission tomography (PET): A validation study using NEMA body phantom.

Authors:  Md Shahidul Islam; Shoichi Watanuki; Manabu Tashiro; Hiroshi Watabe
Journal:  Med Phys       Date:  2018-08-31       Impact factor: 4.071

5.  OLINDA/EXM: the second-generation personal computer software for internal dose assessment in nuclear medicine.

Authors:  Michael G Stabin; Richard B Sparks; Eric Crowe
Journal:  J Nucl Med       Date:  2005-06       Impact factor: 10.057

6.  The AAPM/RSNA physics tutorial for residents: internal radiation dosimetry: principles and applications.

Authors:  R E Toohey; M G Stabin; E E Watson
Journal:  Radiographics       Date:  2000 Mar-Apr       Impact factor: 5.333

7.  Internal absorbed dose estimation by a TLD method for 18F-FDG and comparison with the dose estimates from whole body PET.

Authors:  H M Deloar; T Fujiwara; M Shidahara; T Nakamura; A Yamadera; M Itoh
Journal:  Phys Med Biol       Date:  1999-02       Impact factor: 3.609

8.  Biodistribution and Radiation Dosimetry of 11C-Nicotine from Whole-Body PET Imaging in Humans.

Authors:  Pradeep K Garg; Stephen J Lokitz; Rachid Nazih; Sudha Garg
Journal:  J Nucl Med       Date:  2016-09-22       Impact factor: 10.057

9.  Pediatric radiation dosimetry for positron-emitting radionuclides using anthropomorphic phantoms.

Authors:  Tianwu Xie; Wesley E Bolch; Choonsik Lee; Habib Zaidi
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

10.  Optimized dose regimen for whole-body FDG-PET imaging.

Authors:  Eleonore H de Groot; Nieky Post; Ronald Boellaard; Nils Rl Wagenaar; Antoon Tm Willemsen; Jorn A van Dalen
Journal:  EJNMMI Res       Date:  2013-08-12       Impact factor: 3.138

View more
  3 in total

Review 1.  Medical application of particle and heavy ion transport code system PHITS.

Authors:  Takuya Furuta; Tatsuhiko Sato
Journal:  Radiol Phys Technol       Date:  2021-06-30

2.  Development of PHITS graphical user interface for simulation of positron emitting radioisotopes production in common biological materials during proton therapy.

Authors:  Mehrdad Shahmohammadi Beni; Kwan Ngok Yu; M Rafiqul Islam; Hiroshi Watabe
Journal:  J Radiat Res       Date:  2022-05-18       Impact factor: 2.724

3.  Radiocesium levels in contaminated forests has remained stable, even after heavy rains due to typhoons and localized downpours.

Authors:  Yasuyuki Taira; Masahiko Matsuo; Takumi Yamaguchi; Yumiko Yamada; Makiko Orita; Noboru Takamura
Journal:  Sci Rep       Date:  2020-11-05       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.