Literature DB >> 31415734

Diurnal Variation in Corneal Edema in Fuchs Endothelial Corneal Dystrophy.

Marianne Fritz1, Viviane Grewing1, Philip Maier1, Thabo Lapp1, Daniel Böhringer1, Thomas Reinhard1, Katrin Wacker2.   

Abstract

PURPOSE: The extent of diurnal variation in corneal edema in Fuchs dystrophy is unknown. We measured corneal thickness and posterior profile over the course of the day using Scheimpflug imaging.
DESIGN: Prospective cohort study.
METHODS: Participants with clinically advanced Fuchs dystrophy eyes undergoing endothelial keratoplasty and participants with healthy corneas were assessed around noon the day before surgery and late afternoon, in presumed steady state. After controlled overnight patching to standardize eyelid closure, participants were assessed immediately upon eye opening in hospital the morning of surgery.
RESULTS: Directly upon awakening, patients had mean corneal thickness of 663 μm (interquartile range [IQR], 625-707) in Fuchs dystrophy (n = 44) and controls (n = 11) had thickness of 557 μm (IQR, 527-601). In control corneas, there were no systematic changes with time. In Fuchs dystrophy eyes, corneal thickness decreased after awakening. Ninety-five percent of patients can be expected to have a decrease in corneal thickness over the first 4 hours after awakening between 31 μm and 58 μm (95% prediction interval). Posterior Q decreased on average by 0.15 (95% confidence interval [CI], 0.07-0.23) and posterior radius of curvature decreased by 0.20 mm (95% CI, 0.14-0.27) over the first 4 hours, indicating that edema resolution steepened the central posterior cornea. Beyond 4 hours after awakening, corneas no longer changed considerably in Fuchs dystrophy.
CONCLUSION: Impaired hydration control in clinically advanced Fuchs dystrophy makes measurements of key corneal parameters unreliable directly after eye opening. Beyond the first hours after eye opening, corneal thickness measurements are unlikely to vary more in Fuchs dystrophy eyes than in normal eyes.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2019        PMID: 31415734     DOI: 10.1016/j.ajo.2019.08.002

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  5 in total

1.  Comprehensive Analysis Identified the Circadian Clock and Global Circadian Gene Expression in Human Corneal Endothelial Cells.

Authors:  Hiroko Nakai; Yoshiki Tsuchiya; Nobuya Koike; Taiki Asano; Morio Ueno; Yasuhiro Umemura; Yuh Sasawaki; Ryutaro Ono; Junji Hamuro; Chie Sotozono; Kazuhiro Yagita
Journal:  Invest Ophthalmol Vis Sci       Date:  2022-05-02       Impact factor: 4.925

2.  Correlation of Clinical Fibrillar Layer Detection and Corneal Thickness in Advanced Fuchs Endothelial Corneal Dystrophy.

Authors:  Orlando Özer; Mert Mestanoglu; Antonia Howaldt; Thomas Clahsen; Petra Schiller; Sebastian Siebelmann; Niklas Reinking; Claus Cursiefen; Björn Bachmann; Mario Matthaei
Journal:  J Clin Med       Date:  2022-05-17       Impact factor: 4.964

3.  Corneal Analysis with Swept Source Optical Coherence Tomography in Patients with Coexisting Cataract and Fuchs Endothelial Corneal Dystrophy.

Authors:  Anna Nowińska; Edyta Chlasta-Twardzik; Michał Dembski; Klaudia Ulfik-Dembska; Edward Wylęgała
Journal:  Diagnostics (Basel)       Date:  2021-02-02

Review 4.  Fuchs endothelial corneal dystrophy: The vicious cycle of Fuchs pathogenesis.

Authors:  Stephan Ong Tone; Viridiana Kocaba; Myriam Böhm; Adam Wylegala; Tomas L White; Ula V Jurkunas
Journal:  Prog Retin Eye Res       Date:  2020-05-08       Impact factor: 21.198

5.  Therapeutic contact lens for Fuchs endothelial corneal dystrophy: Monitoring with Scheimpflug tomography.

Authors:  Nir Erdinest; Naomi London; Nadav Levinger; Itay Lavy
Journal:  Am J Ophthalmol Case Rep       Date:  2021-12-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.