The distance between the glottis and the cuff of a tracheal tube placed through three supraglottic airway devices in children: A randomised controlled trial.

Ji-Hyun Lee1, Seoyeong Park, Young-Eun Jang, Eun-Hee Kim, Hee-Soo Kim, Jin-Tae Kim.   

Abstract

BACKGROUND: After tracheal tube insertion via various types of supraglottic airway devices, the distance from the tube cuff to the vocal cords has not been evaluated in children.
OBJECTIVES: The aim of this study was to evaluate the position of a tracheal tube cuff relative to the glottis in children when one of three supraglottic airway devices (I-gel, AuraGain and air-Q laryngeal airway) are used as intubation conduits.
DESIGN: A randomised controlled trial.
SETTING: Tertiary children's hospital. PATIENTS: Children aged less than 7 years. INTERVENTION: In vivo fibre-optic assessment and in vitro measurement. MAIN OUTCOME MEASURES: The main outcome was the safety margin: the distance between the ventilation outlet of the supraglottic airway device and the beginning of the proximal cuff minus that from the ventilation outlet to the glottis. The maximum inner diameter of the cuffed tracheal tube that could be inserted, the fibre-optic view score and the oropharyngeal leak pressure were also evaluated.
RESULTS: The three devices exhibited significant differences in the distance from the ventilation outlet to the glottis (mean ± SD): I-gel 3.6 ± 0.6 cm, AuraGain 3.8 ± 0.7 cm, air-Q 2.8 ± 1.0 cm (P < 0.001). The safety margin was greatest with the air-Q and narrowest with the I-gel: I gel 1.9 ± 1.1 cm, AuraGain 4.4 ± 0.7 cm and air-Q 7.9 ± 1.1 cm. Using the AuraGain and air-Q, the cuffs of the tracheal tubes were predicted to be located below the glottis with one-size and two-size smaller tracheal tubes in all patients. However, using I-gel, the cuffs would be below the glottis in 69% (95% CI 49.6 to 84.5) and 29% (95% CI 14.0 to 48.4) of the patients with a one-size and two-size smaller tube, respectively.
CONCLUSION: The AuraGain and air-Q are well tolerated intubating conduits. The possibility of vocal cord damage is higher when the I-gel is used. TRIAL REGISTRATION: www.clinicaltrials.gov (number: NCT03156166).

Entities:  

Mesh:

Year:  2019        PMID: 31415305     DOI: 10.1097/EJA.0000000000001070

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  3 in total

1.  Optimal Monitoring Technology for Pediatric Thyroidectomy.

Authors:  Daqi Zhang; Hui Sun; Hoon Yub Kim; Antonella Pino; Serena Patroniti; Francesco Frattini; Pietro Impellizzeri; Carmelo Romeo; Gregory William Randolph; Che-Wei Wu; Gianlorenzo Dionigi; Fausto Fama'
Journal:  Cancers (Basel)       Date:  2022-05-24       Impact factor: 6.575

2.  Comparison of the clinical performance of i-gel and Ambu laryngeal masks in anaesthetised paediatric patients: A meta-analysis.

Authors:  Di Bao; Yun Yu; Wei Xiong; Ya-Xin Wang; Yi Liang; Lu Li; Bin Liu; Xu Jin
Journal:  World J Clin Cases       Date:  2022-02-06       Impact factor: 1.337

3.  Dimensional compatibility and limitations of tracheal intubation through supraglottic airway devices: a mannequin-based in vitro study.

Authors:  Berthold Moser; Michael Kemper; Maren Kleine-Brueggeney; Lukas Gasteiger; Markus Weiss
Journal:  Can J Anaesth       Date:  2021-05-20       Impact factor: 5.063

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.