Establishment of the intelligent verification criteria for a routine urinalysis analyzer in a multi-center study.

Li Wang1, Ye Guo2, Jiang Han3, Jing Jin2, Cuiling Zheng1, Junxia Yang3, Jia Xu2, Jiaxing Wang3, Xiaowei Wang2, Yingying Hao2, Wei Wu4, Guijian Liu5, Wei Cui6.   

Abstract

Background Although laboratory information system (LIS) is widely used nowadays, the results of routine urinalysis still need 100% manual verification. We established intelligent verification criteria to perform the automated verification process and reduce manual labor. Methods A total of 4610 urine specimens were obtained from the patients of three hospitals in Beijing, China. Firstly, 895 specimens were measured to establish the reference intervals of formed-element parameters in UF5000. Secondly, 2803 specimens were analyzed for setting up the intelligent verification criteria (including the microscopic review rules and manual verification rules). Lastly, 912 specimens were used to verify the efficacy and accuracy of the intelligent verification criteria. Phase-contrast microscopes were used for the microscopic review. Results Employing a results level corresponding relationship in specific parameters including hemoglobin (red blood cell [RBC]), leukocyte esterase (white blood cell [WBC]) and protein (cast) between the dry-chemistry analysis and formed-element analysis, as well as instrument flags, we established seven WBC verification rules, eight RBC verification rules and four cast verification rules. Based on the microscopy results, through analyzing the pre-set rules mentioned earlier, we finally determined seven microscopic review rules, nine manual verification rules and three auto-verification rules. The microscopic review rate was 21.98% (616/2803), the false-negative rate was 4.32% (121/2803), the total manual verification rate was 35.71% (1001/2803) and the auto-verification rate was 64.29% (1802/2803). The validation results were consistent. Conclusions The intelligent verification criteria for urinary dry-chemistry and urinary formed-element analysis can improve the efficiency of the results verification process and ensure the reliability of the test results.

Entities:  

Keywords:  evaluation; intelligent verification; manual verification rules; microscopic review rules; urinalysis

Mesh:

Year:  2019        PMID: 31415235     DOI: 10.1515/cclm-2019-0344

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  4 in total

1.  What Is the Optimal Timing for Reading the Leukocyte Esterase Strip for the Diagnosis of Periprosthetic Joint Infection?

Authors:  Qing-Yuan Zheng; Rui Li; Ming Ni; Peng Ren; Quan-Bo Ji; Jing-Yang Sun; Jun-Cheng Li; Ji-Ying Chen; Guo-Qiang Zhang
Journal:  Clin Orthop Relat Res       Date:  2021-06-01       Impact factor: 4.755

Review 2.  Application of leukocyte esterase strip test in the screening of periprosthetic joint infections and prospects of high-precision strips.

Authors:  Qing-Yuan Zheng; Guo-Qiang Zhang
Journal:  Arthroplasty       Date:  2020-10-29

3.  Sysmex UN2000 detection of protein/creatinine ratio and of renal tubular epithelial cells can be used for screening lupus nephritis.

Authors:  Yabin Chen; Yuan Zhao; Zhishan Zhang; Xiang Cheng; Jie Lin; Jiaming Li; Yibo Wu; Zhen Zhong Lin; Jing Jing
Journal:  BMC Nephrol       Date:  2022-10-05       Impact factor: 2.585

4.  General position of Croatian medical biochemistry laboratories on autovalidation: survey of the Working Group for Post-analytics of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

Authors:  Vladimira Rimac; Anja Jokic; Sonja Podolar; Jelena Vlasic Tanaskovic; Lorena Honovic; Jasna Lenicek Krleza
Journal:  Biochem Med (Zagreb)       Date:  2020-04-15       Impact factor: 2.313

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.