Literature DB >> 31414568

Cervical shear wave elastography as a predictor of preterm delivery during 18-24 weeks of pregnancy.

Sasiwan Suthasmalee1, Sakita Moungmaithong1.   

Abstract

AIM: The aim of this study was to compare shear wave cervical elasticity between term and preterm delivery group.
METHODS: A prospective cohort study was conducted in enrolled 158 pregnant women at 18-24 weeks of gestation who come for second trimester scan consecutively. Transvaginal ultrasonography for cervical length as well as cervical elasticity in five regions of interest was performed. Intraobserver and interobserver reproducibility were evaluated. Gestational age at deliveries was followed, and cervical shear wave elasticity between term and preterm group was compared.
RESULTS: A total of 158 pregnant women were enrolled in this study while 120 pregnancies data were collected for subsequent analysis, 10 pregnancies spontaneously delivered during the preterm period and 110 pregnancies delivered at term. Intraobserver and interobserver reproducibility were high; however, cervical shear wave elasticity in both groups were not significantly different (external anterior lip 2.29 ± 0.66 and 2.45 ± 0.58 m/s, P value 0.30, internal anterior lip 2.74 ± 0.96 and 2.80 ± 0.61 m/s, P value 0.83). Nonsignificant correlations of cervical shear wave elasticity with gestational age and cervical length (r = -0.1 and r = 0.02, respectively) were demonstrated.
CONCLUSION: Cervical shear wave elasticity in preterm and term groups was not significantly different when measured at 18-24 weeks of gestation. There are nonsignificant correlations between cervical shear wave elasticity, gestational age and cervical length. Cervical shear wave elastography alone should not be used as a predictor for preterm delivery.
© 2019 Japan Society of Obstetrics and Gynecology.

Entities:  

Keywords:  cervical elasticity; cervical length; preterm delivery; shear wave elastography

Mesh:

Year:  2019        PMID: 31414568     DOI: 10.1111/jog.14094

Source DB:  PubMed          Journal:  J Obstet Gynaecol Res        ISSN: 1341-8076            Impact factor:   1.730


  2 in total

1.  Clinical application of cervical shear wave elastography in predicting the risk of preterm delivery in DCDA twin pregnancy.

Authors:  Jimei Sun; Nan Li; Wei Jian; Dingya Cao; Junying Yang; Min Chen
Journal:  BMC Pregnancy Childbirth       Date:  2022-03-14       Impact factor: 3.007

2.  Nomogram Incorporating Multimodal Transvaginal Ultrasound Assessment at 20 to 24 Weeks' Gestation for Predicting Spontaneous Preterm Delivery in Low-Risk Women.

Authors:  Lingli Jiang; Lei Peng; Miaoling Rong; Xiaozhi Liu; Qinxia Pang; Huaping Li; Ying Wang; Zhou Liu
Journal:  Int J Womens Health       Date:  2022-03-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.