Literature DB >> 31410934

Effect of two different temperatures on resistance to cyclic fatigue of one Curve, EdgeFile, HyFlex CM and ProTaper next files.

Hüseyin Sinan Topçuoğlu1, Gamze Topçuoğlu2, Özgür Kafdağ1, Hacer Balkaya3.   

Abstract

This study compared the cyclic fatigue resistance (CFR) of three controlled memory (CM) nickel-titanium rotary files (One Curve, EdgeFile and HyFlex CM) in comparison with a file (ProTaper Next) made from M-wire nickel-titanium alloy at two different temperatures (room and intracanal) in an s-shaped canal. One hundred and sixty files were tested to determine the CFR of OneCurve, EdgeFile, HyFlex CM and ProTaper Next in an artificial canal at room and at intracanal temperature. The number of cycles to failure was recorded, and data were analysed. At both temperatures, ProTaper Next exhibited the lowest CFR compared with the other files (P < 0.05). At room temperature, there was no difference among the three CM files regarding CFR (P > 0.05). At intracanal temperature, OneCurve and EdgeFile exhibited more CFR than the HyFlex CM (P < 0.05). Testing at intracanal temperature caused a significant decrease in CFR of all tested files compared with testing at room temperature.
© 2019 Australian Society of Endodontology Inc.

Entities:  

Keywords:  cyclic fatigue; endodontics; rotary files; s-shaped canal; temperature

Mesh:

Substances:

Year:  2019        PMID: 31410934     DOI: 10.1111/aej.12369

Source DB:  PubMed          Journal:  Aust Endod J        ISSN: 1329-1947            Impact factor:   1.659


  7 in total

1.  Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files.

Authors:  Charlotte Gouédard; Laurent Pino; Reza Arbab-Chirani; Shabnam Arbab-Chirani; Valérie Chevalier
Journal:  Restor Dent Endod       Date:  2022-03-04

2.  Shaping Ability of Reciproc Blue Versus One Curve in Curved Canal: An In-Vitro Study.

Authors:  Mohammad Daher Altufayli; Basem Salim; Imad Katbeh; Razan Merei; Zarina Mamasaidova
Journal:  Cureus       Date:  2022-04-22

3.  Resistance to Cyclic Fatigue of Nickel-Titanium Files Immersed in Sodium Hypochlorite at Body Temperature.

Authors:  Hind F Abuhulaibah; Ammar AbuMostafa
Journal:  Int J Dent       Date:  2020-09-19

4.  Evaluation of the Cyclic Fatigue of Two Single Files at Body and Room Temperature with Different Radii of Curvature.

Authors:  Giusy Rita Maria La Rosa; Valeria Shumakova; Gaetano Isola; Francesco Indelicato; Calogero Bugea; Eugenio Pedullà
Journal:  Materials (Basel)       Date:  2021-04-27       Impact factor: 3.623

5.  Stationary Fatigue Resistance of Various Rotary Instruments with Different Alloys after Preparing Three Root Canals.

Authors:  Afzal Ali; Nihat Umut Gözen; Abdurrahman Kerim Kul; Naveen Chhabra
Journal:  Eur Endod J       Date:  2021-12

Review 6.  Effect of body temperature on the cyclic fatigue resistance of the nickel-titanium endodontic instruments: A systematic review and meta-analysis of in vitro studies.

Authors:  Selventhra Savitha; Sidhartha Sharma; Vijay Kumar; Amrita Chawla; Perumal Vanamail; Ajay Logani
Journal:  J Conserv Dent       Date:  2022-08-02

7.  Influence of kinematics and incidence angles on the cutting efficiency of two single-file nickel-titanium rotary instruments.

Authors:  Eugenio Pedullà; Giusy Rita Maria La Rosa; Giuseppe Romano; Giuseppe Leanza; Silvia Rapisarda; Gaetano Isola; Sebastiano Ferlito; Prasanna Neelakantan; Luigi Generali
Journal:  Aust Endod J       Date:  2021-07-13       Impact factor: 1.719

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.