Literature DB >> 31410525

Small differences in tibial contact locations following kinematically aligned TKA from the native contralateral knee.

Stephanie Nicolet-Petersen1, Augustine Saiz2, Trevor Shelton2, Stephen M Howell1, Maury L Hull3,4,5.   

Abstract

PURPOSE: Kinematically aligned (KA) TKA strives to restore native limb and knee alignments without ligament release with the premise that knee function likewise will be closely restored to native to the extent enabled by the components used. This study determined differences in anterior-posterior (AP) tibial contact locations of a KA TKA performed with asymmetric, fixed bearing, posterior cruciate-retaining (PCR) components from those of the native contralateral knee and also determined the incidence of posterior rim contact of the tibial insert during a deep knee bend and a step-up.
METHODS: Both knees were imaged using single-plane fluoroscopy for 25 patients with a calipered KA TKA and a native knee in the contralateral limb. AP tibial contact locations in each compartment were determined following 3D model-to-2D image registration. Differences in mean AP tibial contact locations in each compartment between the KA TKA knees and the native contralateral knees were analysed. Contact locations either on or beyond the most posterior point of the tibial insert determined the occurrence of posterior rim contact.
RESULTS: Mean AP tibial contact locations for both native and KA TKA knees remained relatively centred in the medial compartment but moved posterior in the lateral compartment during flexion. In both the medial and lateral compartments, differences in mean AP tibial contact locations between the KA TKA knees and the native contralateral knees were more posterior and greatest at 0° flexion for both activities (4 mm, p = 0.0009 and 7 mm, p < 0.0001 for deep knee bend and 6 mm, p < 0.0001 and 8 mm, p < 0.0001 for step-up in the medial and lateral compartments, respectively). The incidence of posterior rim contact of the tibial insert was 16% (4 of 25 patients) but the lowest Oxford Knee Score was 43 for these patients. The median Oxford Knee Score for all patients was 46 (out of 48).
CONCLUSIONS: Calipered KA TKA with asymmetric, fixed bearing, PCR components resulted in mean AP tibial contact locations which were relatively centred in the compartments and differed at most from those of the native contralateral knee by approximately 15% of the AP dimension of a mid-sized tibial baseplate. Although posterior rim contact occurred in some patients, all such patients had high patient-reported outcome scores. LEVEL OF EVIDENCE: Therapeutic, Level III.

Entities:  

Keywords:  Activities of daily living; Contact kinematics; Deep knee bend; Kinematic alignment; Posterior edge loading; Step-up; Tibiofemoral joint; Total knee arthroplasty; Total knee replacement

Year:  2019        PMID: 31410525     DOI: 10.1007/s00167-019-05658-1

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  6 in total

1.  Articulation of the femoral condyle during knee flexion.

Authors:  Guoan Li; Chaochao Zhou; Zhenming Zhang; Timothy Foster; Hany Bedair
Journal:  J Biomech       Date:  2021-12-11       Impact factor: 2.712

2.  Posterior stabilized total knee arthroplasty reproduces natural joint laxity compared to normal in kinematically aligned total knee arthroplasty: a matched pair cadaveric study.

Authors:  In Jun Koh; Christen E Chalmers; Charles C Lin; Soo Bin Park; Michelle H McGarry; Thay Q Lee
Journal:  Arch Orthop Trauma Surg       Date:  2020-10-10       Impact factor: 3.067

3.  Physiological articular contact kinematics and morphological femoral condyle translations of the tibiofemoral joint.

Authors:  Chaochao Zhou; Zhenming Zhang; Zhitao Rao; Timothy Foster; Hany Bedair; Guoan Li
Journal:  J Biomech       Date:  2021-05-15       Impact factor: 2.789

Review 4.  Kinematically Aligned Total Knee Arthroplasty with Patient-Specific Instrument.

Authors:  Kwang Kyoun Kim; Stephen M Howell; Ye Yeon Won
Journal:  Yonsei Med J       Date:  2020-03       Impact factor: 2.759

5.  Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty.

Authors:  Kazuya Kaneda; Yasuo Niki; Yuji Kuroyanagi; Shu Kobayashi; Kengo Harato; Yu Iwama; Takeo Nagura
Journal:  Arthroplast Today       Date:  2021-12-10

6.  More Anterior in vivo Contact Position in Patients With Fixed-Bearing Unicompartmental Knee Arthroplasty During Daily Activities Than in vitro Wear Simulator.

Authors:  Huiyong Dai; Nan Zheng; Diyang Zou; Zhemin Zhu; Ming Han Lincoln Liow; Tsung-Yuan Tsai; Qi Wang
Journal:  Front Bioeng Biotechnol       Date:  2021-05-20
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.