PURPOSE: With the increasing use of minimally invasive surgical techniques for intraocular pressure (IOP) lowering in glaucoma patients, there is a need to examine best practices regarding the postoperative management of these patients. Corticosteroids, though effective in controlling postoperative ocular pain and inflammation, present distinct challenges in glaucoma surgery patients, as their use can be associated with IOP elevation. Loteprednol etabonate (LE) is an ocular corticosteroid designed to have an improved safety profile relative to other corticosteroids.Entities:
Keywords: intraocular pressure; loteprednol etabonate; minimally invasive glaucoma surgery; postoperative pain and inflammation; safety
Year: 2019 PMID: 31409967 PMCID: PMC6645598 DOI: 10.2147/OPTH.S206424
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Minimally invasive glaucoma surgical proceduresa
| MIGS category/IOP-lowering mechanism | Procedure/Device | Manufacturer | FDA approval status |
|---|---|---|---|
| Increasing trabecular flow | Trabectome | Neomedix, Tustin, CA, USA | 2004 |
| iStent | Glaukos Corporation, Laguna Hills, CA, USA | 2012 | |
| iStent inject | Glaukos Corporation, Laguna Hills, CA, USA | 2018 | |
| Hydrus Microstent | Ivantis, Inc, Irvine, CA, USA | 2018 | |
| Gonioscopy-assisted transluminal trabeculotomy (GATT): | Ellex, Adelaide, Australia | 2008 | |
| Excimer laser trabeculotomy (ELT) | Laser probe: AIDA; Glautec AG, Nürnberg, Germany | Under clinical investigation | |
| Ab interno canaloplasty (ABiC): | Ellex, Adelaide, Australia | 2008 | |
| Visco 360 | Sight Sciences, Menlo Park, CA, USA | IDE approval, 2016 | |
| Kahook Dual Blade | New World Medical, Rancho Cucamonga, CA, USA | 2015 | |
| TRAB360 | Sight Sciences, Menlo Park, CA, USA | 2015 | |
| Suprachoroidal shunts | CyPass Micro-Stent | Alcon, Fort Worth, TX, USA | 2016 (withdrawn from market, 2018) |
| iStent Supra | Glaukos Corporation, Laguna Hills, CA | Under clinical investigation | |
| Reducing aqueous production | Endocyclophotocoagulation (ECP) | Curved laser endoscope probe: Endo Optiks, Little Silver, NJ, USA | 1991 |
| Subconjunctival filtration | XEN Glaucoma implant/gel | Allergan, Inc., Irvine, CA, USA | 2016 |
Notes: aMIGS defined as any glaucoma procedure avoiding conjunctival dissection and approached via an ab interno incision (clear corneal wound).
Abbreviation: IDE, investigational device exemption.
Figure 1iStent implanted through the trabecular meshwork into Schlemm’s canal with the assistance of a gonioprism. One can see the snorkel facing the anterior chamber allowing aqueous to flow directly into Schlemm’s canal.
Figure 2CyPass Micro-Stent positioning within the supraciliary space, entering posterior to the scleral spur, using the approved loading device. This Cypass is fully inserted without rings showing and there is no local corneal edema.