Literature DB >> 31409463

A paper-based length of stain analytical device for naked eye (readout-free) detection of cystic fibrosis.

Maryam Taghizadeh-Behbahani1, Bahram Hemmateenejad2, Mojtaba Shamsipur3, Alireza Tavassoli4.   

Abstract

The test of sweat chloride is routinely performed as a worldwide newborn screening (NBS) to the diagnosis of cystic fibrosis (CF) in infants. However, the available methods for measurement of chloride in sweat suffer from such limitations as either low selectivity and/or requiring relatively large sample size. In this work, we have designed an analytical ruler that can measure chloride ion in sweat and hence can be used for the diagnosis of cystic fibrosis. This micro-pad (μ-PAD) device is fabricated by making hydrophilic micro-channel on a filter paper impregnated with silver dichromate. After addition of chloride ion-containing sweat sample, it moves through the channel, leading to the formation of an AgCl sediment, which deposits as a white color stain, the length of which in the channel being proportional to the amount of chloride ion in sweat. A well-defined linear relation was observed between the length of white color stain and the concentration of chloride ion in the sample solutions with a relative standard deviation of 3.6% (n = 3) for an artificial sweat sample containing 100 mM chloride ion. The possible interfering effects of several different cations and anions on the detection of chloride ion were investigated and the results well-confirmed the selectivity of the proposed method. With the use of only 2.0 μL of the sample solution, the μPAD was able to measure the chloride content of sweat over a concentration range of 20.0-100.0 mM, which covers both the healthy range (˂ 40 mM) and the risky range (˃60 mM) of chloride ion. Analysis of chloride content of sweat samples by the μPAD agreed well with those obtained by a standard electrochemical method (with relative errors of lower than 10%).
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chloride ion; Cystic fibrosis; Length of stain; Micro-pad; Paper-based device

Mesh:

Substances:

Year:  2019        PMID: 31409463     DOI: 10.1016/j.aca.2019.06.050

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  2 in total

1.  Electrochemical Detection of Electrolytes Using a Solid-State Ion-Selective Electrode of Single-Piece Type Membrane.

Authors:  Li-Da Chen; Wei-Jhen Wang; Gou-Jen Wang
Journal:  Biosensors (Basel)       Date:  2021-04-07

2.  A Simple Distance Paper-Based Analytical Device for the Screening of Lead in Food Matrices.

Authors:  Kasinee Katelakha; Vanida Nopponpunth; Watcharee Boonlue; Wanida Laiwattanapaisal
Journal:  Biosensors (Basel)       Date:  2021-03-22
  2 in total